Lambda-IgLC Antikörper (APC)
-
- Target Alle Lambda-IgLC Produkte
- Lambda-IgLC (lambda Light Chain (Lambda-IgLC))
-
Reaktivität
- Human
-
Wirt
- Maus
-
Klonalität
- Monoklonal
-
Konjugat
- Dieser Lambda-IgLC Antikörper ist konjugiert mit APC
-
Applikation
- Flow Cytometry (FACS)
- Spezifität
- The mouse monoclonal antibody 1-155-2 recognizes lambda light chains (22.5 kDa) of human immunoglobulin.
- Kreuzreaktivität (Details)
- Human
- Aufreinigung
- Purified antibody is conjugated with activated allophycocyanin (APC) under optimum conditions and unconjugated antibody and free fluorochrome are removed by size-exclusion chromatography.
- Immunogen
- Human IgA1 lambda myeloma protein
- Klon
- 1-155-2
- Isotyp
- IgG1 kappa
-
-
- Applikationshinweise
- Flow cytometry: The reagent is designed for analysis of human blood cells using 10 μL reagent / 100 μL of whole blood or 106 cells in a suspension. The content of a vial (1 ml) is sufficient for 100 tests. Extracellular and intracellular staining.
- Kommentare
-
The purified antibody is conjugated with cross-linked Allophycocyanin (APC) under optimum conditions. The conjugate is purified by size-exclusion chromatography and adjusted for direct use. No reconstitution is necessary.
- Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Rekonstitution
- No reconstitution is necessary.
- Buffer
- Stabilizing phosphate buffered saline (PBS), pH 7.4, 15 mM sodium azide
- Konservierungsmittel
- Sodium azide
- Vorsichtsmaßnahmen
- This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
- Handhabung
-
Do not freeze.
Avoid prolonged exposure to light. - Lagerung
- 4 °C
- Informationen zur Lagerung
- Store at 2-8°C. Protect from prolonged exposure to light. Do not freeze.
-
-
Low levels of monoclonal small B cells in the bone marrow of patients with diffuse large B-cell lymphoma of activated B-cell type but not of germinal center B-cell type." in: Haematologica, Vol. 95, Issue 8, pp. 1334-41, (2010) (PubMed).
: "Splenic marginal zone lymphomas appear to originate from different B cell types." in: The American journal of pathology, Vol. 161, Issue 1, pp. 81-8, (2002) (PubMed).
: "Immunoglobulin isotype expression of normal pre-B cells as determined by immunofluorescence." in: Journal of clinical immunology, Vol. 2, Issue 4, pp. 264-9, (1983) (PubMed).
: "
-
Low levels of monoclonal small B cells in the bone marrow of patients with diffuse large B-cell lymphoma of activated B-cell type but not of germinal center B-cell type." in: Haematologica, Vol. 95, Issue 8, pp. 1334-41, (2010) (PubMed).
-
- Target
- Lambda-IgLC (lambda Light Chain (Lambda-IgLC))
- Andere Bezeichnung
- Lambda light chains (Lambda-IgLC Produkte)
- Hintergrund
- Immunoglobulin classes share the same basic four polypeptide chain structure of two heavy chains (five heavy chains types) and two light chains (kappa, lambda, both having a molecular weight of 22.5 kDa). Kappa and lambda consist of a variable region and a constant region and can easily be differentiated by the antigenic properties of the constant region. The ratio of kappa to lambda is 70:30.,Immunoglobulin lambda, Igl
- Molekulargewicht
- 22.5 kDa
-