Ferritin ELISA Kit
-
- Target Alle Ferritin (FE) ELISA Kits anzeigen
- Ferritin (FE)
-
Reaktivität
- Human
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 0.16 ng/mL - 10 ng/mL
- Untere Nachweisgrenze
- 0.16 ng/mL
- Applikation
- ELISA
- Verwendungszweck
- The kit is a sandwich enzyme immunoassay technique for the in vitro quantitative measurement in various sample types.
- Proben
- Plasma, Serum
- Analytische Methode
- Quantitative
- Spezifität
- This kit recognizes natural and recombinantHumanFE. No significant cross-reactivity or interference between HumanFE and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between HumanFE and all the analogues.
- Kreuzreaktivität (Details)
- No significant cross-reactivity or interference between human Ferritin and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between Human bFGF and all the analogues, therefore, cross reaction may still exist.
- Sensitivität
- 0.09 ng/mL
- Bestandteile
-
- Pre-coated, ready to use 96-well strip plate, flat buttom
- Plate sealer for 96 wells
- Reference Standard
- Reference Standard & Sample Diluent
- Biotinylated Detection Antibody (100 x concentrate)
- HRP Conjugate (100 x concentrate)
- Biotinylated Detection Antibody Diluent
- HRP Conjugate Diluent
- Substrate Reagent
- Stop Solution
- Wash Buffer (25 x concentrate)
- Instruction manual
- Featured
- Zu unserem meistverkauften FE ELISA Kit
-
-
- Applikationshinweise
-
ELISA Plate: The just opened ELISA Plate may appear water-like substance, which is normal and will not have any impact on the experiment results.
Add Sample: The interval of sample adding between the first well and the last well should not be too long, otherwise will cause different pre-incubation time, which will significantly affect the experiment’s accuracy and repeatability. For each step in the procedure, total dispensing time for addition of reagents or samples to the assay plate should not exceed 10 minutes. Parallel measure ment is recommended.
Incubation: To prevent evaporation and ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps. Do not let the strips dry at any time during the assay. Strict compliance with the given incubation time and temperature.
Washing: The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings. Residual liquid in the reaction wells should be pat dry against absorbent paper in the washing process. But don’t put absorbent paper into reaction wells directly. Note that clear the residual liquid and fingerprint in the bottom before measurement, so as not to affect the micro-titer plate reader.
Reagent Preparation: As the volume of Detection Ab and HRP Conjugate is very small, liquid may adhere to the tube wall or tube cap when being transported. You better hand-throw it or centrifugal it for 1 minute at 1000rpm. Please pipette the solution for 4-5 times before pippeting. Please carefully reconstitute Standards, working solutions of Detection Ab and HRP Conjugate according to the instructions. To minimize imprecision caused by pipetting, ensure that pipettors are calibrated. It is recommended to suck more than 10μL for once pipetting. Do not reuse standard solution, working solution of Detection Ab and HRP Conjugate, which have been diluted. If you need to use standard repeatedly, you can divide the standard into small pack according to the amount of each assay, keep them at -20°C to -80°C and avoid repeated freezing and thawing.
Reaction Time Control: Please control reaction time strictly following this product description!
Substrate: Substrate Solution is easily contaminated. Please protect it from light.Stop Solution: As it is an acid solution, please pay attention to the protection of your eyes, hands, face and clothes when using this solution.
Mixing: You’d better use micro-oscillator at the lowest frequency, as sufficient and gentle mixing is particularly important to reaction result. If there is no micro-oscillator available, you can knock the ELISA plate frame gently with your finger before reaction.
Security: Please wear lab coats and latex gloves for protection. Especially detecting samples of blood or other body fluid, please perform following the national security columns of biological laboratories.
Do not use component from different batches of kit(washing buffer and stop solution can be an exception)
To avoid cross-contamination, change pipette tips between adding of each standard level, between sample adding, and between reagent adding. Also, use separate reservoirs for each reagent. Otherwise, the results will be inaccurate! - Kommentare
-
Information on standard material:
The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).
Information on reagents:
Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.
Information on antibodies:
The provided antibodies and their host vary in different kits. All antibodies are affinity purified
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration. - Probenmenge
- 100 µL
- Plattentyp
- Pre-coated
- Protokoll
-
- Add 100 µL standard or sample to each well. Incubate for 90 min at 37 °C.
- Remove the liquid. Add 100 µL Biotinylated Detection Antibody. Incubate for 1 hour at 37 °C.
- Aspirate and wash 3 times.
- Add 100 µL HRP Conjugate. Incubate for 30 min at 37 °C.
- Aspirate and wash 5 times.
- Add 90 µL Substrate Reagent. Incubate for 15 min at 37 °C.
- Add 50 µL Stop Solution. Read at 450 nm immediately.
- Calculation of results.
- Aufbereitung der Reagenzien
-
- Bring all reagents to room temperature (18~25 °C) before use. Follow the Microplate reader manual for set-up and preheat it for 15 min before OD measurement.
- Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer.Note: if crystals have formed in the concentrate, warm it in a 40 °C water bath and mix it gently until the crystals have completely dissolved
- Standard working solution: Centrifuge the standard at 10,000xg for 1 min. Add 1.0 mL of Reference Standard &Sample Diluent, let it stand for 10 min and invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 10 ng/mL. Then make serial dilutions as needed. The recommended dilution gradient is as follows: 10, 5, 2.5, 1.25, 0.63, 0.31, 0.16, 0 ng/mL. Dilution method: Take 7 EP tubes, add 500 μLof Reference Standard & Sample Diluent to each tube. Pipette 500 μLof the 10 ng/mL working solution to the first tube and mix up to produce a 5 ng/mL working solution. Pipette 500 μLof the solution from the former tube into the latter one according to these steps. The illustration below is for reference. Note: the last tube is regarded as a blank. Don't pipette solution into it from the former tube.
- Biotinylated Detection Antibody working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the stock tube before use, dilute the 100x Concentrated Biotinylated Detection Antibody to 1xworking solution with Biotinylated Detection Antibody Diluent.
- Concentrated HRP Conjugate working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Dilute the 100x Concentrated HRP Conjugate to 1x working solution with Concentrated HRP Conjugate Diluent.
- Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- by
- Alamo Laboratories, Inc
- No.
- #029386
- Datum
- 20.11.2013
- Antigen
- Chargennummer
- ELAB-EK-2013-1024-005
- Validierte Anwendung
- Immunohistochemistry
- Positivkontrolle
- Human Sera
- Negativkontrolle
- Goat Sera
- Bewertung
- Signal was detected in positive control samples but not in negative control samples.
- Primärantikörper
- Antigen: Human Ferritin (FE) ELISA Kit - Catalog Number: ABIN1114880
- Lot Number: ELAB-EK-2013-1024-005
- Sekundärantikörper
- Full Protocol
- All reagents in the ELISA kit were brought up to room temperature before use.
- 100 uL of standard or sample were added to wells in ELISA plate pre-coated with capture antibody. All samples and standards were assayed in triplicate.
- The plate was covered with sealer (provided in kit) and incubated for 1.5 h at 37°C. Unbound material was aspirated and 100 uL of Biotin-Antibody (diluted 1:100 in “Diluent for Biotinylated Detection Ab”) was added to each well. Plate was sealed and incubated for 1 h at 37°C. Unbound Biotin-Antibody was removed from each well and plate was washed three times with 350 uL of wash buffer (provided in the kit). After the last wash the plate was inverted against clean absorbent paper to remove any remaining liquid.
- 100 uL of HRP-Conjugate (1X) was added to each well. Plate was sealed and incubated for 1 h at 37°C.
- After 1 h incubation at 37°C, unbound HRP-Avidin was removed by washing five times with 350 uL of wash buffer (provided in the kit). After the last wash the plate was inverted against clean absorbent paper to remove any remaining liquid.
- 90 uL of TMB substrate was added to wells and the plate was covered with a new plate sealer. The plate was tapped to ensure mixing and incubated for 25 min at 37°C in the dark.
- After 25 min, when an apparent gradient appeared in the standard wells, the reaction was terminated by adding 50 uL of Stop Solution to each well.
- The optical density (OD value) of each well was read using a microplate reader set to 450 nm.
- The triplicate readings for each sample were averaged and the average zero standard optical density subtracted to yield ‘corrected absorbance at 450 nm'. A standard curve was generated by plotting the mean OD value for each standard on the X-axis against the concentration on the Y-axis using Excel. Standard curve was generated by regression analysis with four-parameter logistic.
- An equation (y = 0.1983x4 - 0.771x3 + 1.2081x2 + 2.1927x + 0.0425) was derived from the standard curve and used to calculate Ferritin concentrations in samples based on their average absorbance values.
- Anmerkungen
- None
Validierung #029386 (Immunohistochemistry)ValidierungsbilderTable 1: ELISA. Ferritin is present in human serum and undetectable in goat serum. Spike controls indicate no interference in absorbance readings from the diluent used to prepare standards and sera samples. Absorbance readings (OD450 nm)are shown for standard curve, spike controls and unknown samples. Value for avg reading is derived from the average reading of three samples. Avg reading for 0 ng/ml standard was subtracted from all avg readings to yield corrected OD450 nm values for standards, spike controls and unknown samples. Standard deviation is included for all samples. Standard curve was generated by regression analysis with four-parameter logistic. An equation (y = 0.1983x4 - 0.771x3 + 1.2081x2 + 2.1927x + 0.0425 ) was derived from the standard curve and used to calculate Ferritin concentrations shown in Table 1.Protokoll -
- Handhabung
- All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
- Lagerung
- 4 °C/-20 °C
- Informationen zur Lagerung
- The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
-
- Target Alle Ferritin (FE) ELISA Kits anzeigen
- Ferritin (FE)
- Andere Bezeichnung
- Ferritin (FE Produkte)
- Synonyme
- 1HCH ELISA Kit, BEST:LD36673 ELISA Kit, CG2216 ELISA Kit, Dmel\\CG2216 ELISA Kit, FER1 ELISA Kit, FER1HCH ELISA Kit, Fer-L ELISA Kit, Fer1 ELISA Kit, Fer1HC ELISA Kit, FerHCH ELISA Kit, HCH ELISA Kit, T21 ELISA Kit, T9 ELISA Kit, fer1 ELISA Kit, fer1hch ELISA Kit, l(3)00451 ELISA Kit, l(3)j10B4 ELISA Kit, SFerH-1 ELISA Kit, SOF-35 ELISA Kit, SOF-5L ELISA Kit, NV13011 ELISA Kit, ACP1 ELISA Kit, F8A5.24 ELISA Kit, F8A5_24 ELISA Kit, Ferritin 1 heavy chain homologue ELISA Kit, ferritin light chain ELISA Kit, ferritin ELISA Kit, chromosome 26 open reading frame, human C10orf131 ELISA Kit, hyaluronan and proteoglycan link protein 2 ELISA Kit, NAD(P)-linked oxidoreductase superfamily protein ELISA Kit, Fer1HCH ELISA Kit, H-1 ELISA Kit, YPDSF_1340 ELISA Kit, ftnA ELISA Kit, Ft ELISA Kit, C26H10orf131 ELISA Kit, HAPLN2 ELISA Kit, AT1G60730 ELISA Kit
- Hintergrund
- Synonyms: FE
- Pathways
- Transition Metal Ion Homeostasis
-