Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

ST14 ELISA Kit

ST14 Reaktivität: Human Colorimetric Serum
Produktnummer ABIN2648780
  • Target Alle ST14 ELISA Kits anzeigen
    ST14 (Suppression of Tumorigenicity 14 (Colon Carcinoma) (ST14))
    Reaktivität
    Human
    Nachweismethode
    Colorimetric
    Applikation
    ELISA
    Proben
    Serum
    Sensitivität
    2 ng/ml
    Produktmerkmale
    The protein encoded by the Matriptase gene is an epithelial-derived, integral membrane serine protease. This protease forms a complex with the Kunitz-type serine protease inhibitor, HAI-1, and is found to be activated by sphingosine 1-phosphate. This protease has been shown to cleave and activate hepatocyte growth factor/scattering factor, and urokinase plasminogen activator, which suggest the function of this protease as an epithelial membrane activator for other proteases and latent growth factors. The expression of this protease has been associated with breast, colon, prostate, and ovarian tumors, which implicates its role in cancer invasion and metastasis.
    Featured
    Zu unserem meistverkauften ST14 ELISA Kit
    Top Product
    Discover our top product ST14 ELISA Kit
  • Applikationshinweise
    Optimal working dilution should be determined by the investigator.
    Probenmenge
    100 μL
    Testdauer
    2.5 h
    Plattentyp
    Pre-coated
    Protokoll
    The Matriptase (TADG-15) ELISA assay kit is based on the principle of a solid phase enzyme-linked immunosorbent assay. The assay system utilizes a monoclonal antibody directed against a distinct antigenic determinant on the intact Matriptase molecule for solid phase immobilization (on the microtiter wells). Standards, calibrators, and patient samples are incubated with the solid phase antibody on the plate. Wells are then washed and incubated with a biotin conjugated anti-Matriptase monoclonal antibody. After a second wash Streptavidin conjugated to HRP is added as a reporting agent. Excess streptavidin-HRP is then washed off and a solution of TMB Reagent is added and incubated resulting in the development of a blue color if Matriptase is present. The color development is stopped with the addition of Stop Solution changing the color to yellow. The concentration of Matriptase is directly proportional to the color intensity of the test sample. Absorbance is measured spectrophotometrically at 450nm.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    4 °C
  • Target Alle ST14 ELISA Kits anzeigen
    ST14 (Suppression of Tumorigenicity 14 (Colon Carcinoma) (ST14))
    Andere Bezeichnung
    Matriptase (ST14 Produkte)
Sie sind hier:
Kundenservice