Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Urotensin 2 ELISA Kit

UTS2 Reaktivität: Ratte Colorimetric Competition ELISA 0.156-10 ng/mL Plasma, Serum
Produktnummer ABIN4993271
  • Target Alle Urotensin 2 (UTS2) ELISA Kits anzeigen
    Urotensin 2 (UTS2)
    Reaktivität
    • 11
    • 7
    • 5
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Ratte
    Nachweismethode
    Colorimetric
    Methodentyp
    Competition ELISA
    Detektionsbereich
    0.156-10 ng/mL
    Untere Nachweisgrenze
    0.156 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is a competitive enzyme immunoassay for in vitro quantitative measurement of UST2 in Rat serum, plasma and other biological fluids
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This kit recognizes natural and recombinant Rat UST2. No significant cross-reactivity or interference between Rat UST2 and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between Rat UST2 and all the analogues.
    Sensitivität
    0.094 ng/mL
    Bestandteile
    Micro ELISA Plate(Dismountable)
    Reference Standard
    Concentrated Biotinylated Detection Ab (100×)
    Concentrated HRP Conjugate (100×)
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solution
    Plate Sealer
    Product Description
    Certificate of Analysis
    Benötigtes Material
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Featured
    Zu unserem meistverkauften UTS2 ELISA Kit
    Top Product
    Discover our top product UTS2 ELISA Kit
  • Kommentare

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Probenmenge
    50 µL
    Plattentyp
    Pre-coated
    Protokoll
    This ELISA kit uses Competitive-ELISA as the method. The microtiter plate provided in this kit has been pre-coated with UST2. During the reaction, UST2 in the sample or standard competes with a fixed amount of UST2 on the solid phase supporter for sites on the Biotinylated Detection Ab specific to UST2. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of UST2 in the samples is then determined by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Lagerung
    4 °C/-20 °C
    Informationen zur Lagerung
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target Alle Urotensin 2 (UTS2) ELISA Kits anzeigen
    Urotensin 2 (UTS2)
    Andere Bezeichnung
    Urotensin 2 (UST2) (UTS2 Produkte)
    Synonyme
    UTS2 ELISA Kit, ucn2 ELISA Kit, PRO1068 ELISA Kit, U-II ELISA Kit, UCN2 ELISA Kit, UII ELISA Kit, Ucn2 ELISA Kit, prepro-UII ELISA Kit, urotensin 2 ELISA Kit, UTS2 ELISA Kit, uts2 ELISA Kit, Uts2 ELISA Kit
    Pathways
    Negative Regulation of Hormone Secretion