Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

CXCL2 ELISA Kit

Dieses Colorimetric ELISA-Kit wurde entwickelt für die quantitative Messung von Ratte CXCL2.
Produktnummer ABIN4993582

Kurzübersicht für CXCL2 ELISA Kit (ABIN4993582)

Target

Alle CXCL2 ELISA Kits anzeigen
CXCL2 (Chemokine (C-X-C Motif) Ligand 2 (CXCL2))

Reaktivität

  • 7
  • 7
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Ratte

Nachweismethode

Colorimetric

Methodentyp

Sandwich ELISA

Detektionsbereich

62.5-4000 pg/mL

Applikation

ELISA

Proben

Plasma, Serum
  • Untere Nachweisgrenze

    62.5 pg/mL

    Verwendungszweck

    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of MIP-2 in Rat serum, plasma and other biological fluids

    Analytische Methode

    Quantitative

    Spezifität

    This kit recognizes natural and recombinantRatMIP-2. No significant cross-reactivity or interference between RatMIP-2 and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between RatMIP-2 and all the analogues.

    Sensitivität

    37.5 pg/mL

    Bestandteile

    Micro ELISA Plate
    Reference Standard
    Concentrated Biotinylated Detection Ab
    Concentrated HRP Conjugate
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solutio
    Plate Sealer
    Product Description
    Certificate of Analysis

    Benötigtes Material

    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
  • Kommentare

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Probenmenge

    100 µL

    Plattentyp

    Pre-coated

    Protokoll

    This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to MIP-2. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for MIP-2and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain MIP-2, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of MIP-2.You can calculate the concentration of MIP-2in the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.

    Lagerung

    4 °C/-20 °C

    Informationen zur Lagerung

    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target Alle CXCL2 ELISA Kits anzeigen

    CXCL2 (Chemokine (C-X-C Motif) Ligand 2 (CXCL2))

    Andere Bezeichnung

    Macrophage Inflammatory Protein 2 (MIP-2)

    Pathways

    Cellular Response to Molecule of Bacterial Origin
Sie sind hier:
Chat with us!