ACA-IgG ELISA Kit

ACA-IgG Reaktivität: Maus Colorimetric Indirect ELISA 3.125 ng/mL - 200 ng/mL Plasma, Serum, Tissue Homogenate
Produktnummer ABIN5522878
  • Target Alle ACA-IgG Produkte
    ACA-IgG (Anti-Cardiolipin Antibody IgG (ACA-IgG))
    Reaktivität
    • 6
    • 3
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Indirect ELISA
    Detektionsbereich
    3.125 ng/mL - 200 ng/mL
    Untere Nachweisgrenze
    3.125 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    For quantitative detection of ACA-IgG in serum, plasma, tissue homogenates.
    Proben
    Plasma, Serum, Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of ACA-IgG. No significant cross- reactivity or interference between ACA-IgG and analogues was observed. Note: Limited by current skills and knowledge, it is difficult for us to complete the cross-reactivity detection between ACA-IgG and all the analogues, therefore, cross reaction may still exist.
    Sensitivität
    1.875 ng/mL
    Bestandteile
    - ELISA Microplate
    - Lyophilized Standard
    - Sample / Standard Dilution Buffer
    - Biotin-labeled Antibody (Concentrated)
    - Antibody Dilution Buffer
    - HRP-Streptavidin Conjugate(SABC)
    - SABC Dilution Buffer
    - TMB Substrate
    - Stop Solution
    - Wash Buffer (25X)
    - Plate Sealer
    - Product Description
    Benötigtes Material
    - Microplate reader (wavelength: 450nm)
    - 37 °C incubator
    - Automated plate washer
    - Precision single and multi-channel pipette and disposable tips
    - Clean tubes and Eppendorf tubes
    - Deionized or distilled water
  • Applikationshinweise
    Optimal working dilution should be determined by the investigator.
    Kommentare

    Sandwich ELISA, Double Antigen

    Probenmenge
    100 μL
    Plattentyp
    Pre-coated
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    4 °C
    Informationen zur Lagerung
    1. For unopened kit: All the reagents should be kept according to the labels on vials. The Reference Standard and the 96-well stripe plate should be stored at -20 °C upon receipt while the other reagents should be stored at 4 °C.
    2. For used kit: When the kit is used, the remaining reagents need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and zip-seal the foil pouch.
    Haltbarkeit
    6 months