Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

LRG1 ELISA Kit

LRG1 Reaktivität: Human Colorimetric Sandwich ELISA 0.313-20 ng/mL Cell Culture Cells, Cerebrospinal Fluid, Milk, Plasma, Saliva, Serum, Urine
Produktnummer ABIN5564606
  • Target Alle LRG1 ELISA Kits anzeigen
    LRG1 (Leucine-Rich alpha-2 Glycoprotein 1 (LRG1))
    Reaktivität
    • 10
    • 4
    • 4
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.313-20 ng/mL
    Untere Nachweisgrenze
    0.313 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    The AssayMax™ Human LRG1 ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for detection of human LRG1 in plasma, serum, urine, saliva, milk, CSF, and cell culture samples. This assay employs a quantitative sandwich enzyme immunoassay technique that measures human LRG1 in approximately 4 hours. A polyclonal antibody specific for human LRG1 has been pre-coated onto a 96-well microplate with removable strips. LRG1 in standards and samples is sandwiched by the immobilized antibody and biotinylated polyclonal antibody specific for human LRG1, which is recognized by a streptavidin-peroxidase conjugate. All unbound material is washed away and a peroxidase enzyme substrate is added. The color development is stopped and the intensity of the color is measured.
    Marke
    AssayMax™
    Proben
    Cell Culture Cells, Cerebrospinal Fluid, Milk, Plasma, Saliva, Serum, Urine
    Analytische Methode
    Quantitative
    Bestandteile
    Human LRG1 Microplate: A 96-well polystyrene microplate (12 strips of 8 wells) coated with a polyclonal antibody against human LRG1. Sealing Tapes: Each kit contains 3 precut, pressure sensitive sealing tapes that can be cut to fit the format of the individual assay. Human LRG1 Standard: Human LRG1 in a buffered protein base (32 ng, lyophilized). Biotinylated Human LRG1 Antibody (50x): A 50-fold concentrated biotinylated polyclonal antibody against human LRG1 (120 l). MIX Diluent Concentrate (10x): A 10-fold concentrated buffered protein base (30 ml). Wash Buffer Concentrate (20x): A 20-fold concentrated buffered surfactant (30 ml, 2 bottles). Streptavidin-Peroxidase Conjugate (SP Conjugate): A 100-fold concentrate (80 l). Chromogen Substrate: A ready-to-use stabilized peroxidase chromogen substrate tetramethylbenzidine (8 ml). Stop Solution: A 0.5 N hydrochloric acid to stop the chromogen substrate reaction (12 ml).
    Benötigtes Material
    Microplate reader capable of measuring absorbance at 405 nm. Pipettes (1-20 µL, 20-200 µL, and multiple channel). Deionized or distilled reagent grade water Incubator (37 °C)
    Featured
    Zu unserem meistverkauften LRG1 ELISA Kit
    Top Product
    Discover our top product LRG1 ELISA Kit
  • Testdauer
    5 h
    Plattentyp
    Pre-coated
    Protokoll
    • Step 1. Add 50 μL of Standard or Sample per well. Incubate 2 hours.
    • Step 2. Wash, then add 50 μL of Biotinylated Antibody per well. Incubate 1 hour.
    • Step 3. Wash, then add 50 μL of SP Conjugate per well. Incubate 30 minutes.
    • Step 4. Wash, then add 50 μL of Chromogen Substrate per well. Incubate 20 minutes.
    • Step 5. Add 50 μL of Stop Solution per well. Read at 450 nm immediately.
    Aufbereitung der Reagenzien

    Freshly dilute all reagents and bring all reagents to room temperature before use. MIX Diluent Concentrate (10x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the MIX Diluent Concentrate 10-fold with reagent grade water. Store for up to 30 days at 2-8 °C. Human LRG1 Standard: Reconstitute the Human LRG1 Standard (32 ng) with 1.6 mL of MIX Diluent to generate a 20 ng/mL standard stock solution. Allow the standard to sit for 10 minutes with gentle agitation prior to making dilutions. Prepare duplicate or triplicate standard points by serially diluting from the standard stock solution (20 ng/mL) 2-fold with MIX Diluent to produce 10, 5, 2.5, 1.25, 0.625, and 0.313 ng/mL solutions. MIX Diluent serves as the zero standard (0 ng/mL). Any remaining stock solution should be frozen at -20 °C and used within 30 days. 5 Standard Point Dilution [Human LRG1] (ng/mL) P1 1 part Standard (20 ng/mL) 20 P2 1 part P1 + 1 part MIX Diluent 10 P3 1 part P2 + 1 part MIX Diluent 5.0 P4 1 part P3 + 1 part MIX Diluent 2.5 P5 1 part P4 + 1 part MIX Diluent 1.25 P6 1 part P5 + 1 part MIX Diluent 0.625 P7 1 part P6 + 1 part MIX Diluent 0.313 P8 MIX Diluent 0.0 Biotinylated Human LRG1 Antibody (50x): Spin down the antibody briefly and dilute the desired amount of the antibody 50-fold with MIX Diluent. The undiluted antibody should be stored at -20 °C. Wash Buffer Concentrate (20x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the Wash Buffer Concentrate 20-fold with reagent grade water. SP Conjugate (100x): Spin down the SP Conjugate briefly and dilute the desired amount of the conjugate 100-fold with MIX Diluent. The undiluted conjugate should be stored at -20 °C.

    Probennahme
    Plasma: Collect plasma using one-tenth volume of 0.1 M sodium citrate as an anticoagulant. Centrifuge samples at 3000 x g for 10 minutes and collect plasma. A 10000-fold sample dilution is suggested into MIX Diluent, however, user should determine optimal dilution factor depending on application needs. The undiluted samples can be stored at -20 °C or below for up to 3 months. Avoid repeated freeze-thaw cycles (EDTA or Heparin can also be used as an anticoagulant). Serum: Samples should be collected into a serum separator tube. After clot formation, centrifuge samples at 3000 x g for 10 minutes and remove serum. A 10000-fold sample dilution is suggested into MIX Diluent, however, user should determine optimal dilution factor depending on application needs. The undiluted samples can be stored at -20 °C or below for up to 3 months. Avoid repeated freeze-thaw cycles. Urine: Collect urine using sample pot. Centrifuge samples at 800 x g for 10 minutes. The sample is suggested for use at 1x, however, user should determine optimal dilution factor depending on application needs. The undiluted samples can be stored at -20 ° C or below for up to 3 months. Avoid repeated freeze-thaw cycles. Saliva: Collect saliva using sample tube. Centrifuge samples at 800 x g for 10 minutes. A 50-fold sample dilution is suggested into MIX Diluent, however, user should determine optimal dilution factor depending on application needs. The undiluted samples can be stored at -20 ° C or below for up to 3 months. Avoid repeated freeze-thaw cycles. Milk: Collect milk using sample tube. Centrifuge samples at 800 x g for 10 minutes. A 500-fold sample dilution is suggested into MIX Diluent, however, user should determine optimal dilution factor depending on application needs. The undiluted samples can be stored at -20 ° C or below for up to 3 months. Avoid repeated freeze-thaw cycles. CSF: Collect cerebrospinal fluid (CSF) using sample pot. Centrifuge samples at 3000 x g for 10 minutes. A 50-fold sample dilution is suggested into MIX Diluent, however, user should determine optimal dilution factor depending on application needs. The undiluted samples can be stored at -80 °C for up to 3 months. Avoid repeated freeze-thaw cycles. 4 Cell Culture Supernatants: Centrifuge cell culture media at 3000 x g for 10 minutes at 4 °C to remove debris and collect supernatants. Samples can be stored at -20 °C or below. Avoid repeated freeze-thaw cycles. Refer to Sample Dilution Guidelines for further instruction. Guidelines for Dilutions of 100-fold or Greater (for reference only, please follow the insert for specific dilution suggested) 100x 10000x A) 4 μL sample: 396 μL buffer (100x) = 100-fold dilution Assuming the needed volume is less than or equal to 400 μL. A) 4 μL sample : 396 μL buffer (100x) B) 4 μL of A : 396 μL buffer (100x) = 10000-fold dilution Assuming the needed volume is less than or equal to 400 μL. 1000x 100000x A) 4 μL sample : 396 μL buffer (100x) B) 24 μL of A : 216 μL buffer (10x) = 1000-fold dilution Assuming the needed volume is less than or equal to 240 μL. A) 4 μL sample : 396 μL buffer (100x) B) 4 μL of A : 396 μL buffer (100x) C) 24 μL of B : 216 μL buffer (10x) = 100000-fold dilution Assuming the needed volume is less than or equal to 240 μL.
    Testdurchführung

    Prepare all reagents, standard solutions, and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature (20-25 °C). Remove excess microplate strips from the plate frame and return them immediately to the foil pouch with desiccants inside. Reseal the pouch securely to minimize exposure to water vapor and store in a vacuum desiccator. Add 50 l of Human LRG1 Standard or sample to each well. Gently tap plate to thoroughly coat the wells. Break any bubbles that may have formed. Cover wells with a sealing tape and incubate for 2 hours. Start the timer after the last addition. Wash five times with 200 l of Wash Buffer manually. Invert the plate each time and decant the contents, hit 4-5 times on absorbent material to completely remove the liquid. If using a machine, wash six times with 300 l of Wash Buffer and then invert the plate, decanting the contents, hit 4-5 times on absorbent material to completely remove the liquid. Add 50 l of Biotinylated Human LRG1 Antibody to each well. Gently tap plate to thoroughly coat the wells. Break any bubbles that may have formed. Cover wells with a sealing tape and incubate for 1 hour. Wash the microplate as described above. 6 Add 50 l of Streptavidin-Peroxidase Conjugate to each well. Gently tap plate to thoroughly coat the wells. Break any bubbles that may have formed. Cover wells with a sealing tape and incubate for 30 minutes. Turn on the microplate reader and set up the program in advance. Wash the microplate as described above. Add 50 l of Chromogen Substrate to each well. Gently tap plate to thoroughly coat the wells. Break any bubbles that may have formed. Incubate for 20 minutes or until the optimal blue color density develops. Add 50 l of Stop Solution to each well. The color will change from blue to yellow. Gently tap plate to ensure thorough mixing. Break any bubbles that may have formed. Read the absorbance on a microplate reader at a wavelength of 450 nm immediately. If wavelength correction is available, subtract readings at 570 nm from those at 450 nm to correct optical imperfections. Otherwise, read the plate at 450 nm only. Please note that some unstable black particles may be generated at high concentration points after stopping the reaction for about 10 minutes, which will reduce the readings.

    Ergebnisberechnung
    • Calculate the mean value of the duplicate or triplicate readings for each standard and sample.
    • To generate a standard curve, plot the graph using the standard concentrations on the x-axis and the corresponding mean 450 nm absorbance (OD) on the y-axis. The best-fit line can be determined by regression analysis using log-log or four-parameter logistic curve-fit.
    • Determine the unknown sample concentration from the standard curve and multiply the value by the dilution factor.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    This product is for Research Use Only and is not intended for use in diagnostic procedures. Prepare all reagents (diluent buffer, wash buffer, standard, biotinylated antibody, and SP conjugate) as instructed, prior to running the assay. Prepare all samples prior to running the assay. The dilution factors for the samples are suggested in this insert. However, the user should determine the optimal dilution factor. 2 Spin down the SP conjugate vial and the biotinylated antibody vial before opening and using contents. The Stop Solution is an acidic solution. The kit should not be used beyond the expiration date.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    Upon arrival, immediately store components of the kit at recommended temperatures up to the expiration date. Store SP Conjugate and Biotinylated Antibody at -20°C. Store Microplate, Diluent Concentrate (10x), Wash Buffer, Stop Solution, and Chromogen Substrate at 2-8°C. Unused microplate wells may be returned to the foil pouch with the desiccant packs and resealed. May be stored for up to 30 days in a vacuum desiccator. Diluent (1x) may be stored for up to 30 days at 2-8°C. Store Standard at 2-8°C before reconstituting with Diluent and at -20°C after reconstituting with Diluent. 3
  • Target Alle LRG1 ELISA Kits anzeigen
    LRG1 (Leucine-Rich alpha-2 Glycoprotein 1 (LRG1))
    Andere Bezeichnung
    Leucine-rich Alpha-2-Glycoprotein (LRG1) (LRG1 Produkte)
    Synonyme
    lrg ELISA Kit, HMFT1766 ELISA Kit, LRG ELISA Kit, 1300008B03Rik ELISA Kit, 2310031E04Rik ELISA Kit, Lrg ELISA Kit, Lrhg ELISA Kit, si:dkey-90m5.4 ELISA Kit, leucine rich alpha-2-glycoprotein 1 ELISA Kit, leucine-rich alpha-2-glycoprotein 1 L homeolog ELISA Kit, leucine-rich alpha-2-glycoprotein 1 ELISA Kit, perilipin-5 ELISA Kit, si:dkey-90m5.4 ELISA Kit, LRG1 ELISA Kit, lrg1.L ELISA Kit, Lrg1 ELISA Kit, PLIN5 ELISA Kit
    Hintergrund
    Leucine-rich alpha-2-glycoprotein, in humans, is a protein that is encoded by the LRG1 gene. LRG1 belongs to the leucine-rich repeat (LRR) family of proteins, which has been shown to be involved in cell adhesion and development, protein-protein interaction, and signal transduction. Additionally, LRG1 has been shown to be involved in the promotion of neovascularization, causing a switch in transforming growth factor beta (TGF- beta) signaling in endothelial cells. LRG1 binds to the accessory receptor endoglin and promotes signaling via the ALK1-Smad1/5/8 pathway. LRG1 is expressed during granulocyte differentiation (1, 2).
    Gen-ID
    116844
    UniProt
    P02751
    Pathways
    Brown Fat Cell Differentiation
Sie sind hier:
Kundenservice