UROS ELISA Kit
-
- Target Alle UROS Produkte
- UROS (Uroporphyrinogen III Synthase (UROS))
- Reaktivität
- Human
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 0.312 ng/mL - 20 ng/mL
- Untere Nachweisgrenze
- 0.312 ng/mL
- Applikation
- ELISA
- Verwendungszweck
- The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of UROS in human serum, plasma, tissue homogenates and other biological fluids.
- Proben
- Plasma, Serum, Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of this index.
- Sensitivität
- 0.114 ng/mL
- Bestandteile
-
- Pre-coated, ready to use 96-well strip plate
- Standard (freeze dried)
- Standard Diluent
- Detection Reagent A
- Detection Reagent B
- Assay Diluent A
- Assay Diluent B
- TMB
- Stop Solution
- Wash Buffer (30X)
- Plate sealer for 96 wells
- Instruction manual
- Benötigtes Material
-
- Microplate reader with 450 ± 10nm filter.
- Precision single or multi-channel pipettes and disposable tips.
- Eppendorf Tubes for diluting samples.
- Deionized or distilled water.
- Absorbent paper for blotting the microtiter plate.
- Container for Wash Solution.
-
- Probenmenge
- 100 μL
- Testdauer
- 1 - 4.5 h
- Plattentyp
- Pre-coated
- Protokoll
-
1. Prepare all reagents, samples and standards
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4. Aspirate and wash 3 times
5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6. Aspirate and wash 5 times
7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8. Add 50µL Stop Solution. Read at 450nm immediately. - Testdurchführung
-
The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Testpräzision
-
- Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
- Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
- CV(%) = SD/meanX100
- Intra-assay: CV<10%
- Inter-assay: CV<12%
- Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Vorsichtsmaßnahmen
- The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
- Handhabung
- The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
- Haltbarkeit
- 12 months
-
- Target Alle UROS Produkte
- UROS (Uroporphyrinogen III Synthase (UROS))
- Abstract
- UROS Produkte
- Synonyme
- wu:fd13d11 ELISA Kit, zgc:110240 ELISA Kit, UROIIIS ELISA Kit, Afu6g12800 ELISA Kit, UROS ELISA Kit, MGC85561 ELISA Kit, AI415298 ELISA Kit, Uros3 ELISA Kit, ARABIDOPSIS THALIANA UROPORPHYRINOGEN III SYNTHASE ELISA Kit, ATDUF3 ELISA Kit, ATUROS ELISA Kit, DOMAIN OF UNKNOWN FUNCTION 724 3 ELISA Kit, DUF3 ELISA Kit, T9J22.21 ELISA Kit, T9J22_21 ELISA Kit, UROPORPHYRINOGEN III SYNTHASE ELISA Kit, uroporphyrinogen III synthase ELISA Kit, uroporphyrinogen-III synthase (UroS) ELISA Kit, uroporphyrinogen-iii synthase ELISA Kit, uroporphyrinogen III synthase L homeolog ELISA Kit, uroporphyrinogen-III synthase family protein ELISA Kit, uros ELISA Kit, UROS ELISA Kit, AFUA_6G12800 ELISA Kit, UroS ELISA Kit, uros.L ELISA Kit, Uros ELISA Kit, HEMD ELISA Kit
- Hintergrund
- Alternative name: UROIIIS, Hydroxymethylbilane hydrolyase, Uroporphyrinogen-III cosynthase
- Gen-ID
- 7390
- UniProt
- P10746
-