AZGP1 CLIA Kit
-
- Target Alle AZGP1 CLIA Kits anzeigen
- AZGP1 (alpha-2-Glycoprotein 1, Zinc-Binding (AZGP1))
-
Reaktivität
- Human
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 9.38 ng/mL - 600 ng/mL
- Untere Nachweisgrenze
- 9.38 ng/mL
- Applikation
- ELISA
- Proben
- Plasma, Saliva, Seminal Plasma, Serum, Sweat, Urine
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1). No significant cross-reactivity or interference between Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) and analogues was observed.
- Sensitivität
- 0.35 ng/mL
- Featured
- Zu unserem meistverkauften AZGP1 ELISA Kit
- Top Product
- Discover our top product AZGP1 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle AZGP1 CLIA Kits anzeigen
- AZGP1 (alpha-2-Glycoprotein 1, Zinc-Binding (AZGP1))
- Andere Bezeichnung
- Alpha-2-Glycoprotein 1, Zinc Binding (AZGP1 Produkte)
- Synonyme
- Zag CLIA Kit, ZA2G CLIA Kit, ZAG CLIA Kit, ZA2GA CLIA Kit, Zna2gp CLIA Kit, alpha-2-glycoprotein 1, zinc CLIA Kit, alpha-2-glycoprotein 1, zinc-binding CLIA Kit, Azgp1 CLIA Kit, AZGP1 CLIA Kit
- Hintergrund
-
Gene Name: Alpha-2-Glycoprotein 1, Zinc Binding
Gene Aliases: ZA2G, ZAG
- Gen-ID
- 563
- UniProt
- P25311
- Pathways
- Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process
-