Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

C8G CLIA Kit

C8G Reaktivität: Human Chemiluminescent Sandwich ELISA 78.12 pg/mL - 5000 pg/mL Plasma, Serum
Produktnummer ABIN5653260
  • Target Alle C8G CLIA Kits anzeigen
    C8G (Complement Component 8, gamma Polypeptide (C8G))
    Reaktivität
    • 3
    • 1
    Human
    Nachweismethode
    Chemiluminescent
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    78.12 pg/mL - 5000 pg/mL
    Untere Nachweisgrenze
    78.12 pg/mL
    Applikation
    ELISA
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Complement Component 8g (C8g). No significant cross-reactivity or interference between Complement Component 8g (C8g) and analogues was observed.
    Sensitivität
    2.69 pg/mL
    Top Product
    Discover our top product C8G ELISA Kit
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer
    2 - 3 h
    Plattentyp
    Pre-coated
    Protokoll
    The microplate provided in this kit has been pre-coated with an antibody specific to Complement Component 8g (C8g). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Complement Component 8g (C8g). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Complement Component 8g (C8g) level in the sample or standard.,
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 8g (C8g) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 8g (C8g) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Haltbarkeit
    4-8 months
  • Target Alle C8G CLIA Kits anzeigen
    C8G (Complement Component 8, gamma Polypeptide (C8G))
    Andere Bezeichnung
    Complement Component 8g (C8G Produkte)
    Synonyme
    C8C CLIA Kit, complement C8 gamma chain CLIA Kit, complement component 8, gamma polypeptide CLIA Kit, C8G CLIA Kit, C8g CLIA Kit
    Hintergrund

    Gene Name: Complement Component 8g

    Gen-ID
    733
    UniProt
    P07360
    Pathways
    Komplementsystem
Sie sind hier:
Kundenservice