EZH2 CLIA Kit

EZH2 Reaktivität: Human Chemiluminescent Sandwich ELISA 156.25 pg/mL - 10000 pg/mL Tissue Homogenate
Produktnummer ABIN5653875
  • Target Alle EZH2 CLIA Kits anzeigen
    EZH2 (Enhancer of Zeste Homolog 2 (EZH2))
    Reaktivität
    • 4
    • 3
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Chemiluminescent
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    156.25 pg/mL - 10000 pg/mL
    Untere Nachweisgrenze
    156.25 pg/mL
    Applikation
    ELISA
    Proben
    Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Enhancer Of Zeste Homolog 2 (EZH2). No significant cross-reactivity or interference between Enhancer Of Zeste Homolog 2 (EZH2) and analogues was observed.
    Sensitivität
    5.69 pg/mL
    Top Product
    Discover our top product EZH2 ELISA Kit
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer
    2 - 3 h
    Plattentyp
    Pre-coated
    Protokoll
    The microplate provided in this kit has been pre-coated with an antibody specific to Enhancer Of Zeste Homolog 2 (EZH2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Enhancer Of Zeste Homolog 2 (EZH2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Enhancer Of Zeste Homolog 2 (EZH2) level in the sample or standard.,
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Enhancer Of Zeste Homolog 2 (EZH2) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Enhancer Of Zeste Homolog 2 (EZH2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Haltbarkeit
    4-8 months
  • Target Alle EZH2 CLIA Kits anzeigen
    EZH2 (Enhancer of Zeste Homolog 2 (EZH2))
    Andere Bezeichnung
    Enhancer Of Zeste Homolog 2 (EZH2 Produkte)
    Synonyme
    ENX-1 CLIA Kit, ENX1 CLIA Kit, EZH1 CLIA Kit, EZH2b CLIA Kit, KMT6 CLIA Kit, KMT6A CLIA Kit, WVS CLIA Kit, WVS2 CLIA Kit, eya2 CLIA Kit, im:7149338 CLIA Kit, zgc:136376 CLIA Kit, zgc:152758 CLIA Kit, EZH2 CLIA Kit, enx-1 CLIA Kit, enx1 CLIA Kit, ezh1 CLIA Kit, kmt6 CLIA Kit, xez CLIA Kit, Enx-1 CLIA Kit, Enx1h CLIA Kit, mKIAA4065 CLIA Kit, ezh2 CLIA Kit, olezh2 CLIA Kit, enhancer of zeste 2 polycomb repressive complex 2 subunit CLIA Kit, enhancer of zeste 2 polycomb repressive complex 2 subunit L homeolog CLIA Kit, enhancer of zeste 2 polycomb repressive complex 2 subunit S homeolog CLIA Kit, EZH2 CLIA Kit, ezh2 CLIA Kit, Ezh2 CLIA Kit, ezh2.L CLIA Kit, ezh2.S CLIA Kit
    Hintergrund

    Gene Name: Enhancer Of Zeste Homolog 2

    Gene Aliases: ENX-1, KMT6, KMT6A, Histone-lysine N-methyltransferase EZH2, Lysine N-methyltransferase 6

    Gen-ID
    2146
    UniProt
    Q15910
    Pathways
    Retinoic Acid Receptor Signaling Pathway, Regulation of Muscle Cell Differentiation
Kundenservice