Estriol CLIA Kit

Reaktivität: Diverse Spezies Chemiluminescent Competition ELISA 781.25 pg/mL - 200000 pg/mL Plasma, Serum
Produktnummer ABIN5653985
  • Target Alle Estriol CLIA Kits anzeigen
    Estriol
    Reaktivität
    • 3
    • 1
    Diverse Spezies
    Nachweismethode
    Chemiluminescent
    Methodentyp
    Competition ELISA
    Detektionsbereich
    781.25 pg/mL - 200000 pg/mL
    Untere Nachweisgrenze
    781.25 pg/mL
    Applikation
    ELISA
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Estriol (E3). No significant cross-reactivity or interference between Estriol (E3) and analogues was observed.
    Sensitivität
    262.3 pg/mL
    Top Product
    Discover our top product Estriol ELISA Kit
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer
    2 h
    Plattentyp
    Pre-coated
    Protokoll
    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Estriol (E3). A competitive inhibition reaction is launched between biotin labeled Estriol (E3) and unlabeled Estriol (E3) (Standards or samples) with the pre-coated antibody specific to Estriol (E3). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Estriol (E3) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Estriol (E3) level in the sample or standard.
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Estriol (E3) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Estriol (E3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Haltbarkeit
    4-8 months
  • Target Alle Estriol CLIA Kits anzeigen
    Estriol
    Abstract
    Estriol Produkte
    Substanzklasse
    Hormone
    Hintergrund

    Gene Name: Estriol