GLN1 CLIA Kit
-
- Target Alle GLN1 CLIA Kits anzeigen
- GLN1 (Glutamine Synthetase (GLN1))
-
Reaktivität
- Maus
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 3.12 pg/mL - 200 pg/mL
- Untere Nachweisgrenze
- 3.12 pg/mL
- Applikation
- ELISA
- Proben
- Cerebrospinal Fluid, Plasma, Serum
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Glutamine synthetase (GS). No significant cross-reactivity or interference between Glutamine synthetase (GS) and analogues was observed.
- Sensitivität
- 0.11 pg/mL
- Featured
- Zu unserem meistverkauften GLN1 ELISA Kit
- Top Product
- Discover our top product GLN1 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Glutamine synthetase (GS). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Glutamine synthetase (GS). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Glutamine synthetase (GS) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutamine synthetase (GS) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutamine synthetase (GS) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle GLN1 CLIA Kits anzeigen
- GLN1 (Glutamine Synthetase (GLN1))
- Andere Bezeichnung
- Glutamine synthetase (GLN1 Produkte)
- Synonyme
- GLNS CLIA Kit, GS CLIA Kit, PIG43 CLIA Kit, PIG59 CLIA Kit, Glns CLIA Kit, glutamate-ammonia ligase CLIA Kit, glutamate-ammonia ligase (glutamine synthetase) CLIA Kit, glutamine synthetase CLIA Kit, GLUL CLIA Kit, Glul CLIA Kit, GLN1 CLIA Kit
- Hintergrund
-
Gene Name: Glutamine synthetase
Gene Aliases: GLNS, GLUL, Glutamate-Ammonia Ligase, Glutamate decarboxylase
- Gen-ID
- 14645
- UniProt
- P15105
- Pathways
- Positive Regulation of Peptide Hormone Secretion
-