IFNA4 CLIA Kit

IFNa4 Reaktivität: Human Chemiluminescent Sandwich ELISA 31.25 pg/mL - 2000 pg/mL Plasma, Serum
Produktnummer ABIN5655570
  • Target Alle IFNA4 (IFNa4) CLIA Kits anzeigen
    IFNA4 (IFNa4) (Interferon, alpha 4 (IFNa4))
    Reaktivität
    • 3
    • 1
    Human
    Nachweismethode
    Chemiluminescent
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    31.25 pg/mL - 2000 pg/mL
    Untere Nachweisgrenze
    31.25 pg/mL
    Applikation
    ELISA
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Interferon Alpha 4 (IFNa4). No significant cross-reactivity or interference between Interferon Alpha 4 (IFNa4) and analogues was observed.
    Sensitivität
    1.26 pg/mL
    Top Product
    Discover our top product IFNa4 ELISA Kit
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer
    2 - 3 h
    Plattentyp
    Pre-coated
    Protokoll
    The microplate provided in this kit has been pre-coated with an antibody specific to Interferon Alpha 4 (IFNa4). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interferon Alpha 4 (IFNa4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interferon Alpha 4 (IFNa4) level in the sample or standard.,
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interferon Alpha 4 (IFNa4) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interferon Alpha 4 (IFNa4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Haltbarkeit
    4-8 months
  • Target Alle IFNA4 (IFNa4) CLIA Kits anzeigen
    IFNA4 (IFNa4) (Interferon, alpha 4 (IFNa4))
    Andere Bezeichnung
    Interferon Alpha 4 (IFNa4 Produkte)
    Synonyme
    IFN-alpha4a CLIA Kit, INFA4 CLIA Kit, Ifa4 CLIA Kit, interferon alpha 4 CLIA Kit, interferon, alpha 4 CLIA Kit, interferon-alpha-4 CLIA Kit, IFNA4 CLIA Kit, Ifna4 CLIA Kit, LOC100052921 CLIA Kit
    Hintergrund

    Gene Name: Interferon Alpha 4

    Gene Aliases: INFA4, Interferon Alpha-4B, Interferon Alpha-76, Interferon Alpha-M1

    UniProt
    P05014
    Pathways
    JAK-STAT Signalweg, Hepatitis C