CXCL11 CLIA Kit
-
- Target Alle CXCL11 CLIA Kits anzeigen
- CXCL11 (Chemokine (C-X-C Motif) Ligand 11 (CXCL11))
-
Reaktivität
- Human
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 31.25 pg/mL - 2000 pg/mL
- Untere Nachweisgrenze
- 31.25 pg/mL
- Applikation
- ELISA
- Proben
- Plasma, Serum
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Interferon Inducible T-Cell Alpha Chemoattractant (ITaC). No significant cross-reactivity or interference between Interferon Inducible T-Cell Alpha Chemoattractant (ITaC) and analogues was observed.
- Sensitivität
- 1.26 pg/mL
- Featured
- Zu unserem meistverkauften CXCL11 ELISA Kit
- Top Product
- Discover our top product CXCL11 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Interferon Inducible T-Cell Alpha Chemoattractant (ITaC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interferon Inducible T-Cell Alpha Chemoattractant (ITaC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interferon Inducible T-Cell Alpha Chemoattractant (ITaC) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interferon Inducible T-Cell Alpha Chemoattractant (ITaC) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interferon Inducible T-Cell Alpha Chemoattractant (ITaC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle CXCL11 CLIA Kits anzeigen
- CXCL11 (Chemokine (C-X-C Motif) Ligand 11 (CXCL11))
- Andere Bezeichnung
- Interferon Inducible T-Cell Alpha Chemoattractant (CXCL11 Produkte)
- Synonyme
- H174 CLIA Kit, I-TAC CLIA Kit, IP-9 CLIA Kit, IP9 CLIA Kit, SCYB11 CLIA Kit, SCYB9B CLIA Kit, b-R1 CLIA Kit, Cxc11 CLIA Kit, I-tac CLIA Kit, Ip9 CLIA Kit, Itac CLIA Kit, Scyb11 CLIA Kit, Scyb9b CLIA Kit, betaR1 CLIA Kit, C-X-C motif chemokine ligand 11 CLIA Kit, chemokine (C-X-C motif) ligand 11 CLIA Kit, CXCL11 CLIA Kit, Cxcl11 CLIA Kit
- Hintergrund
-
Gene Name: Interferon Inducible T-Cell Alpha Chemoattractant
Gene Aliases: CXCL11, I-TAC, IP9, SCYB11, SCYB9B, B-R1, Chemokine(C-X-C-Motif)ligand 11, Small Inducible Cytokine Subfamily B Member 11, Interferon gamma-inducible protein 9
- Gen-ID
- 6373
- UniProt
- O14625
-