IL32 CLIA Kit
-
- Target Alle IL32 CLIA Kits anzeigen
- IL32 (Interleukin 32 (IL32))
-
Reaktivität
- Human
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 15.62 pg/mL - 1000 pg/mL
- Untere Nachweisgrenze
- 15.62 pg/mL
- Applikation
- ELISA
- Proben
- Plasma, Serum
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Interleukin 32 (IL32). No significant cross-reactivity or interference between Interleukin 32 (IL32) and analogues was observed.
- Sensitivität
- 0.5 pg/mL
- Featured
- Zu unserem meistverkauften IL32 ELISA Kit
- Top Product
- Discover our top product IL32 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 32 (IL32). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 32 (IL32). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 32 (IL32) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 32 (IL32) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 32 (IL32) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle IL32 CLIA Kits anzeigen
- IL32 (Interleukin 32 (IL32))
- Andere Bezeichnung
- Interleukin 32 (IL32 Produkte)
- Synonyme
- IL-32alpha CLIA Kit, IL-32beta CLIA Kit, IL-32delta CLIA Kit, IL-32gamma CLIA Kit, NK4 CLIA Kit, TAIF CLIA Kit, TAIFa CLIA Kit, TAIFb CLIA Kit, TAIFc CLIA Kit, TAIFd CLIA Kit, interleukin 32 CLIA Kit, IL32 CLIA Kit
- Hintergrund
-
Gene Name: Interleukin 32
Gene Aliases: NK4, TAIF, TAIFb, TAIFd, Natural Killer Cell Transcript 4, Natural killer cells protein 4, Tumor necrosis factor alpha-inducing factor
-