MT1E ELISA Kit
-
- Target Alle MT1E ELISA Kits anzeigen
- MT1E (Metallothionein 1E (MT1E))
-
Reaktivität
- Human
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 0.312 ng/mL - 20 ng/mL
- Untere Nachweisgrenze
- 0.312 ng/mL
- Applikation
- ELISA
- Proben
- Plasma, Serum, Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Metallothionein 1E (MT1E). No significant cross-reactivity or interference between Metallothionein 1E (MT1E) and analogues was observed.
- Sensitivität
- 0.112 ng/mL
- Featured
- Zu unserem meistverkauften MT1E ELISA Kit
- Top Product
- Discover our top product MT1E ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Metallothionein 1E (MT1E). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Metallothionein 1E (MT1E). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Metallothionein 1E (MT1E), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Metallothionein 1E (MT1E) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Metallothionein 1E (MT1E) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Metallothionein 1E (MT1E) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle MT1E ELISA Kits anzeigen
- MT1E (Metallothionein 1E (MT1E))
- Andere Bezeichnung
- Metallothionein 1E (MT1E Produkte)
- Synonyme
- MT-IA ELISA Kit, MT1 ELISA Kit, MTD ELISA Kit, MGC140492 ELISA Kit, MT ELISA Kit, metallothionein 1A ELISA Kit, metallothionein 1E ELISA Kit, metallothionein-1E ELISA Kit, MT1A ELISA Kit, MT1E ELISA Kit, MT1D ELISA Kit
- Hintergrund
-
Gene Name: Metallothionein 1E
Gene Aliases: MTD
- Gen-ID
- 4493
- UniProt
- P04732
-