CCL7 ELISA Kit
-
- Target Alle CCL7 ELISA Kits anzeigen
- CCL7 (Chemokine (C-C Motif) Ligand 7 (CCL7))
-
Reaktivität
- Maus
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 15.62 pg/mL - 1000 pg/mL
- Untere Nachweisgrenze
- 15.62 pg/mL
- Applikation
- ELISA
- Proben
- Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Monocyte Chemotactic Protein 3 (MCP3). No significant cross-reactivity or interference between Monocyte Chemotactic Protein 3 (MCP3) and analogues was observed.
- Sensitivität
- 5.6 pg/mL
- Featured
- Zu unserem meistverkauften CCL7 ELISA Kit
- Top Product
- Discover our top product CCL7 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Monocyte Chemotactic Protein 3 (MCP3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Monocyte Chemotactic Protein 3 (MCP3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Monocyte Chemotactic Protein 3 (MCP3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Monocyte Chemotactic Protein 3 (MCP3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle CCL7 ELISA Kits anzeigen
- CCL7 (Chemokine (C-C Motif) Ligand 7 (CCL7))
- Andere Bezeichnung
- Monocyte Chemotactic Protein 3 (CCL7 Produkte)
- Synonyme
- CCL7 ELISA Kit, FIC ELISA Kit, MARC ELISA Kit, MCP-3 ELISA Kit, MCP3 ELISA Kit, NC28 ELISA Kit, SCYA6 ELISA Kit, SCYA7 ELISA Kit, Scya7 ELISA Kit, fic ELISA Kit, marc ELISA Kit, mcp3 ELISA Kit, C-C motif chemokine ligand 7 ELISA Kit, chemokine (C-C motif) ligand 7 ELISA Kit, CCL7 ELISA Kit, Ccl7 ELISA Kit
- Hintergrund
-
Gene Name: Monocyte Chemotactic Protein 3
Gene Aliases: CCL7, FIC, MARC, NC28, MCP3, SCYA7, Chemokine C-C-Motif Ligand 7, Small Inducible Cytokine A7, Monocyte Chemoattractant Protein 3
- Gen-ID
- 20306
- UniProt
- Q03366
-