PLA2G2D ELISA Kit
-
- Target Alle PLA2G2D ELISA Kits anzeigen
- PLA2G2D (Phospholipase A2, Group IID (PLA2G2D))
-
Reaktivität
- Human
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 0.312 ng/mL - 20 ng/mL
- Untere Nachweisgrenze
- 0.312 ng/mL
- Applikation
- ELISA
- Proben
- Plasma, Serum, Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Phospholipase A2, Group IID (PLA2G2D). No significant cross-reactivity or interference between Phospholipase A2, Group IID (PLA2G2D) and analogues was observed.
- Sensitivität
- 0.135 ng/mL
- Featured
- Zu unserem meistverkauften PLA2G2D ELISA Kit
- Top Product
- Discover our top product PLA2G2D ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Phospholipase A2, Group IID (PLA2G2D). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Phospholipase A2, Group IID (PLA2G2D). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Phospholipase A2, Group IID (PLA2G2D), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Phospholipase A2, Group IID (PLA2G2D) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phospholipase A2, Group IID (PLA2G2D) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phospholipase A2, Group IID (PLA2G2D) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle PLA2G2D ELISA Kits anzeigen
- PLA2G2D (Phospholipase A2, Group IID (PLA2G2D))
- Andere Bezeichnung
- Phospholipase A2, Group IID (PLA2G2D Produkte)
- Synonyme
- PLA2IID ELISA Kit, SPLASH ELISA Kit, sPLA2-IID ELISA Kit, sPLA2S ELISA Kit, Splash ELISA Kit, mGIID ELISA Kit, phospholipase A2 group IID ELISA Kit, phospholipase A2, group IID ELISA Kit, PLA2G2D ELISA Kit, Pla2g2d ELISA Kit
- Hintergrund
-
Gene Name: Phospholipase A2, Group IID
Gene Aliases: PLA2G2D, sPLA2S, s-PLA2, sPLA2, SPLASH, Secreted Phospholipase A2, Phosphatidylcholine 2-acylhydrolase 2D, Secretory-type PLA, stroma-associated homolog
- Pathways
- Inositol Metabolic Process
-