PLA2G7 CLIA Kit
-
- Target Alle PLA2G7 (Lp-PLA2) CLIA Kits anzeigen
- PLA2G7 (Lp-PLA2) (Lipoprotein-Associated phospholipase A2 (Lp-PLA2))
-
Reaktivität
- Human
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 156.25 pg/mL - 10000 pg/mL
- Untere Nachweisgrenze
- 156.25 pg/mL
- Applikation
- ELISA
- Proben
- Plasma, Serum
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Phospholipase A2, Lipoprotein Associated (LpPLA2). No significant cross-reactivity or interference between Phospholipase A2, Lipoprotein Associated (LpPLA2) and analogues was observed.
- Sensitivität
- 4.81 pg/mL
- Featured
- Zu unserem meistverkauften Lp-PLA2 ELISA Kit
- Top Product
- Discover our top product Lp-PLA2 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Phospholipase A2, Lipoprotein Associated (LpPLA2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Phospholipase A2, Lipoprotein Associated (LpPLA2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Phospholipase A2, Lipoprotein Associated (LpPLA2) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phospholipase A2, Lipoprotein Associated (LpPLA2) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phospholipase A2, Lipoprotein Associated (LpPLA2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle PLA2G7 (Lp-PLA2) CLIA Kits anzeigen
- PLA2G7 (Lp-PLA2) (Lipoprotein-Associated phospholipase A2 (Lp-PLA2))
- Andere Bezeichnung
- Phospholipase A2, Lipoprotein Associated (Lp-PLA2 Produkte)
- Synonyme
- LDL-PLA2 CLIA Kit, LP-PLA2 CLIA Kit, PAFAD CLIA Kit, PAFAH CLIA Kit, Lp-PLA2 CLIA Kit, PAF-AH CLIA Kit, R75400 CLIA Kit, zgc:77563 CLIA Kit, phospholipase A2 group VII CLIA Kit, phospholipase A2, group VII (platelet-activating factor acetylhydrolase, plasma) CLIA Kit, PLA2G7 CLIA Kit, Pla2g7 CLIA Kit, pla2g7 CLIA Kit
- Hintergrund
-
Gene Name: Phospholipase A2, Lipoprotein Associated
Gene Aliases: PLA2G7, PAF-AH, PAFAH, Lp-PLA2, LDL-PLA2, Platelet Activating Factor Acetylhydrolase,Plasma, Phospholipase A2,Group VII, LDL-associated phospholipase A2
- Gen-ID
- 7941
- UniProt
- Q13093
- Pathways
- Peptide Hormone Metabolism
-