Reelin CLIA Kit
-
- Target Alle Reelin (RELN) CLIA Kits anzeigen
- Reelin (RELN)
-
Reaktivität
- Ratte
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 15.62 pg/mL - 1000 pg/mL
- Untere Nachweisgrenze
- 15.62 pg/mL
- Applikation
- ELISA
- Proben
- Plasma, Serum, Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Reelin (RL). No significant cross-reactivity or interference between Reelin (RL) and analogues was observed.
- Sensitivität
- 0.64 pg/mL
- Featured
- Zu unserem meistverkauften RELN ELISA Kit
- Top Product
- Discover our top product RELN ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Reelin (RL). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Reelin (RL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Reelin (RL) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Reelin (RL) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Reelin (RL) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle Reelin (RELN) CLIA Kits anzeigen
- Reelin (RELN)
- Andere Bezeichnung
- Reelin (RELN Produkte)
- Synonyme
- LIS2 CLIA Kit, PRO1598 CLIA Kit, RL CLIA Kit, reeler CLIA Kit, rl CLIA Kit, Reelen CLIA Kit, Rl CLIA Kit, reln CLIA Kit, RELN CLIA Kit, MGC172539 CLIA Kit, reelin CLIA Kit, reelin L homeolog CLIA Kit, RELN CLIA Kit, Reln CLIA Kit, reln CLIA Kit, reln.L CLIA Kit, LOC579060 CLIA Kit
- Hintergrund
-
Gene Name: Reelin
Gene Aliases: RELN
- Gen-ID
- 24718
- UniProt
- P58751
- Pathways
- Synaptic Membrane
-