Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

Ribonuclease A8 ELISA Kit

Reaktivität: Human Colorimetric Sandwich ELISA 0.312 ng/mL - 20 ng/mL Tissue Homogenate
Produktnummer ABIN5658501
  • Target Alle Ribonuclease A8 Produkte
    Ribonuclease A8
    Reaktivität
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.312 ng/mL - 20 ng/mL
    Untere Nachweisgrenze
    0.312 ng/mL
    Applikation
    ELISA
    Proben
    Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of Ribonuclease A8 (RNASE8). No significant cross-reactivity or interference between Ribonuclease A8 (RNASE8) and analogues was observed.
    Sensitivität
    0.109 ng/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer
    3 h
    Plattentyp
    Pre-coated
    Protokoll
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ribonuclease A8 (RNASE8). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ribonuclease A8 (RNASE8). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ribonuclease A8 (RNASE8), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ribonuclease A8 (RNASE8) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ribonuclease A8 (RNASE8) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ribonuclease A8 (RNASE8) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Handhabung
    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Haltbarkeit
    4-8 months
  • Target Alle Ribonuclease A8 Produkte
    Ribonuclease A8
    Abstract
    Ribonuclease A8 Produkte
    Hintergrund

    Gene Name: Ribonuclease A8

    Gene Aliases: Rnase-A8, Ribonuclease,RNase A Family,8

    UniProt
    Q8TDE3