UROD ELISA Kit
-
- Target Alle UROD ELISA Kits anzeigen
- UROD (Uroporphyrinogen Decarboxylase (UROD))
-
Reaktivität
- Ratte
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 0.312 ng/mL - 20 ng/mL
- Untere Nachweisgrenze
- 0.312 ng/mL
- Applikation
- ELISA
- Proben
- Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Uroporphyrinogen Decarboxylase (UROD). No significant cross-reactivity or interference between Uroporphyrinogen Decarboxylase (UROD) and analogues was observed.
- Sensitivität
- 0.117 ng/mL
- Featured
- Zu unserem meistverkauften UROD ELISA Kit
- Top Product
- Discover our top product UROD ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Uroporphyrinogen Decarboxylase (UROD). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Uroporphyrinogen Decarboxylase (UROD). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Uroporphyrinogen Decarboxylase (UROD), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Uroporphyrinogen Decarboxylase (UROD) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Uroporphyrinogen Decarboxylase (UROD) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Uroporphyrinogen Decarboxylase (UROD) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle UROD ELISA Kits anzeigen
- UROD (Uroporphyrinogen Decarboxylase (UROD))
- Andere Bezeichnung
- Uroporphyrinogen Decarboxylase (UROD Produkte)
- Hintergrund
-
Gene Name: Uroporphyrinogen Decarboxylase
Gene Aliases: PCT, Uroporphyrinogen III Decarboxylase
- UniProt
- P32362
-