WFS1 CLIA Kit
-
- Target Alle WFS1 CLIA Kits anzeigen
- WFS1 (Wolfram Syndrome 1 (WFS1))
-
Reaktivität
- Maus
- Nachweismethode
- Chemiluminescent
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 156.25 pg/mL - 10000 pg/mL
- Untere Nachweisgrenze
- 156.25 pg/mL
- Applikation
- ELISA
- Proben
- Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of Wolfram Syndrome Protein 1 (WFS1). No significant cross-reactivity or interference between Wolfram Syndrome Protein 1 (WFS1) and analogues was observed.
- Sensitivität
- 6 pg/mL
- Top Product
- Discover our top product WFS1 ELISA Kit
-
-
- Kommentare
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Testdauer
- 2 - 3 h
- Plattentyp
- Pre-coated
- Protokoll
- The microplate provided in this kit has been pre-coated with an antibody specific to Wolfram Syndrome Protein 1 (WFS1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Wolfram Syndrome Protein 1 (WFS1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Wolfram Syndrome Protein 1 (WFS1) level in the sample or standard.,
- Testpräzision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wolfram Syndrome Protein 1 (WFS1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wolfram Syndrome Protein 1 (WFS1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Handhabung
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Haltbarkeit
- 4-8 months
-
- Target Alle WFS1 CLIA Kits anzeigen
- WFS1 (Wolfram Syndrome 1 (WFS1))
- Andere Bezeichnung
- Wolfram Syndrome Protein 1 (WFS1 Produkte)
- Synonyme
- WFRS CLIA Kit, WFS CLIA Kit, WFSL CLIA Kit, CG4917 CLIA Kit, Dmel\\CG4917 CLIA Kit, GB15257 CLIA Kit, WFS1 CLIA Kit, AI481085 CLIA Kit, wolframin CLIA Kit, wfs1 CLIA Kit, wolframin ER transmembrane glycoprotein CLIA Kit, wolfram syndrome 1 CLIA Kit, wolframin CLIA Kit, Wolfram syndrome 1 (wolframin) L homeolog CLIA Kit, Wfs1 CLIA Kit, WFS1 CLIA Kit, wfs1 CLIA Kit, LOC552818 CLIA Kit, CpipJ_CPIJ013087 CLIA Kit, wfs1.L CLIA Kit
- Hintergrund
-
Gene Name: Wolfram Syndrome Protein 1
Gene Aliases: DFNA14, DFNA38, DFNA6, DIDMOAD, WFRS, WFS, Wolframin
- Pathways
- Sensory Perception of Sound, Carbohydrate Homeostasis, ER-Nucleus Signaling, Negative Regulation of intrinsic apoptotic Signaling, SARS-CoV-2 Protein Interaktom
-