Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

CST3 ELISA Kit

CST3 Reaktivität: Human Colorimetric Sandwich ELISA Plasma (EDTA), Plasma (heparin), Serum, Tissue Culture Medium, Urine
Produktnummer ABIN577654
  • Target Alle CST3 ELISA Kits anzeigen
    CST3 (Cystatin C (CST3))
    Reaktivität
    • 13
    • 13
    • 9
    • 5
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Untere Nachweisgrenze
    0.171 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    The DetectX® Human Cystatin C kit is designed to quantitatively measure human Cystatin C present in biological samples and tissue culture media.
    Marke
    DetectX®
    Proben
    Serum, Plasma (EDTA), Plasma (heparin), Urine, Tissue Culture Medium
    Analytische Methode
    Quantitative
    Spezifität
    Sample Types validated: Serum, EDTA and Heparin Plasma, Urine and Tissue Culture Media
    Kreuzreaktivität (Details)
    A serum sample was spiked with varying concentrations of bilirubin, diluted 1:50 in Assay Buffer and tested in the assay.
    Bilirubin levels in normal serum are between 0.2 and 1.0 mg/ dL11.
    At 10 times the highest concentration normally seen in human samples there was a 14 % decrease in measured Cystatin C concentration.
    A serum sample was spiked with varying concentrations of hemoglobin in the form of RBCs, diluted 1:100 in Assay Buffer and tested in the assay.
    No significant change to the measured Cystatin C level was observed.
    A serum sample was spiked with varying concentrations of lipids, diluted 1:50 in Assay Buffer and tested in the assay.
    No significant change to the measured Cystatin C level was observed with the addition of high, medium and low levels of lipids.
    Dog, monkey, rat and mouse serum samples were serially diluted in the Assay Buffer and tested in the assay.
    No Cystatin C was detected.
    This kit should not be used for non-human samples.
    Sensitivität
    0.058 ng/mL
    Produktmerkmale
    The Cystatin C Immunoassay Kit is designed to measure Human Cystatin C levels in a variety of biological matrices. This kit uses a microtiter plate coated with a monoclonal to Cystatin C and a native human Cystatin C molecule standard. Samples and standards are added to the plate and after an hour incubation at RT the plate is washed and monoclonal antibody-peroxidase conjugate is added. After a 30-minute incubation at RT, the plate is washed and TMB substrate solution added to each well. The color reaction is read at 450nm. Cystatin C is a non-glycosylated protein of low molecular weight (13kDa) in the cystatin superfamily. Cystatin C is produced at a constant rate in all nucleated cells. Cystatin C belongs to the cysteine proteinase inhibitor group and is associated with several pathological conditions. Imbalance between Cystatin C and cysteine proteinases is associated with diseases such as inflammation, renal failure, cancer, Alzheimer's disease, multiple sclerosis and hereditary Cystatin C amyloid angiopathy. Cystatin C is removed from blood plasma by glomerular filtration in the kidneys. It is reabsorbed by the proximal tubular cells and degraded. There is a linear relationship between the reciprocal Cystatin C concentration in plasma and the glomerular filtration rate (GFR). Cystatin C is suggested to be a better marker for GFR than other markers as its serum concentration is not affected by other factors such as age, gender and body mass. There is association of Cystatin C levels with the incidence of myocardial infarction and coronary death, presenting a risk factor for secondary cardiovascular events.
    Bestandteile
    Clear Coated 96 Well Plate One Plate Clear plastic microplate with break-apart strips coated with mouse anti-human Cystatin C.
    Cystatin C Standard 60 μL A stock solution of native human Cystatin C at 400 ng/mL.
    DetectX® Cystatin C Conjugate 5 mL A monoclonal antibody to Cystatin C labeled with peroxidase.
    Assay Buffer Concentrate 28 mL A 5X concentrate that should be diluted with deionized or distilled water.
    Wash Buffer Concentrate 30 mL A 20X concentrate that should be diluted with deionized or distilled water.
    TMB Substrate 5 mL
    Stop Solution 5 mL A 1N hydrochloric acid solution. Caustic.
    Plate Sealer 1 each
    Benötigtes Material
    Distilled or deionized water.
    A microplate washer.
    Colorimetric 96 well microplate reader capable of reading optical density at 450 nm, preferably with correction between 570 and 590 nm.
    Software for converting raw relative optical density readings from the plate reader and carrying out four parameter logistic curve (4PLC) fitting.
    Contact your plate reader manufacturer for de- tails.
    Featured
    Zu unserem meistverkauften CST3 ELISA Kit
    Top Product
    Discover our top product CST3 ELISA Kit
  • Applikationshinweise
    This assay has been validated for human serum, EDTA and heparin plasma, urine and tissue culture media (TCM) samples only.
    Samples containing visible particulate should be centrifuged prior to using.
    This assay has been shown to detect Cystatin C from human samples only.
    Kommentare

    Sample values: Thirteen random human serum samples were tested in the assay.
    Values ranged from 532.0 to 905.6 ng/mL with an average of 675 ng/mL.
    The normal reference range for serum Cystatin C is 590-910 ng/mL10.
    An abnormal serum sample read at 1,384 ng/mL.

    Testdauer
    2 h
    Plattentyp
    Pre-coated
    Protokoll
    A human Cystatin C standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve.
    Standards or diluted samples are pipetted into a clear microtiter plate coated with a monoclonal antibody to capture the Cystatin C present.
    After a 60 minute incubation, the plate is washed and a peroxidase conjugated Cystatin C monoclonal antibody is added.
    The plate is again incubated for 30 minutes and washed.
    Sub- strate is then added to the plate, which reacts with the bound Cystatin C Antibody Conjugate.
    Af- ter a third incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450 nm wavelength.
    The concentration of the Cystatin C in the sample is calculated, after making suitable correction for dilution, using software available with most plate readers.
    Aufbereitung der Reagenzien

    Allow the kit reagents to come to room temperature for 30 minutes.
    We recommend that all standards and samples be run in duplicate to allow the end user to accurately determine Cystatin C concentrations.
    Ensure that all samples have reached room temperature and have been diluted as appropriate prior to running them in the kit.
    Assay Buffer Dilute Assay Buffer Concentrate 1:5 by adding one part of the concentrate to four parts of deion- ized water.
    Once diluted this is stable at 4 °C for 3 months.
    Wash Buffer Dilute Wash Buffer Concentrate 1:20 by adding one part of the concentrate to nineteen parts of deionized water.
    Once diluted this is stable at room temperature for 3 months.
    Standard Preparation Label seven glass test tubes as #1 through #7.
    Briefly spin vial of standard in a microcentrifuge to ensure contents are at bottom of vial.
    Pipet 585 μL of Assay Buffer into tube #1 and 250 μL into tubes #2 to #7.
    Carefully add 15 μL of the Cystatin C stock solution to tube #1 and vortex completely.
    Take 250 μL of the Cystatin C solution in tube #1 and add it to tube #2 and vortex completely.
    Repeat the serial dilutions for tubes #3 through #7.
    The concentration of Cystatin C in tubes #1 through #7 will be 10, 5, 2.5, 1.25, 0.625, 0.313 and 0.156 ng/mL.
    Use all Standards within 2 hours of preparation.

    Aufbereitung der Proben

    Serum and plasma samples must be diluted ≥ 1:50 with the provided Assay Buffer prior to running in the kit. A dilution of ≥ 1:225 is recommended to detect most samples within the standard curve range. Disease state samples, such as those from tubular kidney disease, may require further dilu- tions up to 1:500 or greater. It is up to the end user to determine the appropriate dilution for their samples. Urine samples must be diluted ≥ 1:4 with the provided Assay Buffer prior to running in the kit. TCM samples should be diluted in TCM and read off a standard curve generated in the same TCM. Any samples with Cystatin C concentrations outside the standard curve range should be diluted further with Assay Buffer or TCM, as appropriate, to obtain readings within the standard curve. Use all samples within 2 hours of dilution.

    Testdurchführung
    1. Use the plate layout sheet on the back page of the insert to aid in proper sample and standard identification. Determine the number of wells to be used and return unused wells to foil pouch with desiccant. Seal the ziploc plate bag and store at 4ºC.
      2. Pipet 50 μL of samples or standards into wells in the plate. Pipet 50 μL of Assay Buffer into the zero standard wells.
      3. Incubate at room temperature for 60 minutes. Aspirate the plate and wash each well 4 times with 300 μL wash buffer. Tap the plate dry on clean absorbent towels.
      4. Add 50 μL of the DetectX® Cystatin C Conjugate to each well, using a repeater pipet.
      5. Incubate at room temperature for 30 minutes.
      6. Aspirate the plate and wash each well 4 times with 300 μL wash buffer. Tap the plate dry on clean absorbent towels.
      7. Add 50 μL of the TMB Substrate to each well, using a repeater pipet.
      8. Incubate the plate at room temperature for 30 minutes.
      9. Add 50 μL of the Stop Solution to each well, using a repeater pipet. 10. Read the optical density generated from each well in a plate reader capable of reading at 450 nm. 11. Use the plate reader's built-in 4PLC software capabilities to calculate Cystatin C concentration for each sample.
    Ergebnisberechnung

    Average the duplicate OD readings for each standard and sample.
    Create a standard curve by reducing the data using computer software capable of generating a four-parameter logistic curve (4PLC) fit.
    The sample concentrations should be multiplied by the dilution factor to obtain neat sample values.
    Or use the online tool from http://www.myassays.com/arbor-assays-cystatin-c-immunoassay-kit.assay to calculate the data. *The MyAssays logo is a registered trademark of MyAssays Ltd. tyPical data Sample Mean OD Human Cystatin C Conc. (ng/mL) Standard 1 1.595 10 Standard 2 0.810 5 Standard 3 0.399 2.5 Standard 4 0.221 1.25 Standard 5 0.129 0.625 Standard 6 0.082 0.313 Standard 7 0.061 0.156 B0 0.042 0 Sample 1 0.636 3.76 Sample 2 0.094 0.40 Always run your own standard curve for calculation of results.
    Do not use this data.

    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen
    As with all such products, this kit should only be used by qualified personnel who have had labo- ratory safety instruction.
    The complete insert should be read and understood before attempting to use the product.
    The antibody coated plate needs to be stored desiccated.
    The silica gel pack included in the foil ziploc bag will keep the plate dry.
    The silica gel pack will turn from blue to pink if the ziploc has not been closed properly.
    The Cystatin C Standard is purified from a human source and as such, should be treated as poten- tially hazardous.
    Proper safety procedures must be followed.
    This kit utilizes a peroxidase-based readout system.
    Buffers, including other manufacturers Wash Buffers, containing sodium azide will inhibit color production from the enzyme.
    Make sure all buffers used for samples are azide free.
    Ensure that any plate washing system is rinsed well with deionized water prior to using the supplied Wash Buffer as prepared on Page 8.
    The Stop Solution is acid.
    The solution should not come in contact with skin or eyes.
    Take appro- priate precautions when handling this reagent.
    Lagerung
    4 °C,RT
    Informationen zur Lagerung
    All components of this kit should be stored at 4 °C until the expiration date of the kit.
  • Villela-Torres, Higareda-Mendoza, Gómez-García, Alvarez-Paredes, García-López, Stenvikel, Gu, Rashid-Qureshi, Lindholm, Alvarez-Aguilar: "Copeptin Plasma Levels are Associated With Decline of Renal Function in Patients With Type 2 Diabetes Mellitus." in: Archives of medical research, (2018) (PubMed).

    Barbati, Cappuccini, Aisa, Grasselli, Zamarra, Bini, Bellomo, Orlacchio, Di Renzo: "Increased Urinary Cystatin-C Levels Correlate with Reduced Renal Volumes in Neonates with Intrauterine Growth Restriction." in: Neonatology, Vol. 109, Issue 2, pp. 154-60, (2016) (PubMed).

    Asnani, Reid: "Cystatin C: a useful marker of glomerulopathy in sickle cell disease?" in: Blood cells, molecules & diseases, Vol. 54, Issue 1, pp. 65-70, (2014) (PubMed).

  • Target Alle CST3 ELISA Kits anzeigen
    CST3 (Cystatin C (CST3))
    Andere Bezeichnung
    Cystatin C (CST3 Produkte)
    Synonyme
    armd11 ELISA Kit, fb51d07 ELISA Kit, wu:fb24g06 ELISA Kit, wu:fb51d07 ELISA Kit, wu:fc55f03 ELISA Kit, zgc:136227 ELISA Kit, ARMD11 ELISA Kit, CysC ELISA Kit, CYSC ELISA Kit, cystatin C ELISA Kit, cystatin C L homeolog ELISA Kit, cystatin C (amyloid angiopathy and cerebral hemorrhage) ELISA Kit, cystatin 3 ELISA Kit, CST3 ELISA Kit, cst3.L ELISA Kit, cst3 ELISA Kit, cystatin 3 ELISA Kit, Cst3 ELISA Kit
    Hintergrund
    Cystatin C is a non-glycosylated protein of low molecular weight (13 kDa) in the cystatin superfam- ily. Cystatin C is produced at a constant rate in all nucleated cells, secreted from cells and thus found in detectable amounts in most body fluids1,2. Cystatin C belongs to the cysteine proteinase inhibitor group and is associated with several pathological conditions. Imbalance between Cys- tatin C and cysteine proteinases is associated with diseases such as inflammation, renal failure, cancer, Alzheimer's disease, multiple sclerosis and hereditary Cystatin C amyloid angiopathy1,3,4. Increased levels have been found in autoimmune diseases, with colorectal tumors and metasta- ses, patients with inflammation and in patients on dialysis5,6,7. Cystatin C is removed from blood plasma by glomerular filtration in the kidneys. It is reabsorbed by the proximal tubular cells and degraded. There is a linear relationship between the reciprocal Cystatin C concentration in plasma and the glomerular filtration rate (GFR). Cystatin C is suggested to be a better marker for GFR than the ubiquitous serum creatinine marker as its serum concentration is not affected by other factors such as age, gender and body mass and Cystatin C has higher sensitivity to detect a re- duced GFR than creatinine determination2,5. Low levels of Cystatin C are found with the break- down of the elastic laminae and atherosclerosis and abdominal aortic aneurysm8. There is evident association of Cystatin C levels with the incidence of myocardial infarction, coronary death and angina pectoris, presenting a risk factor for secondary cardiovascular events9
Sie sind hier:
Kundenservice