CCL19 ELISA Kit

CCL19 Reaktivität: Maus Colorimetric Sandwich ELISA 5-1000 pg/mL Cell Culture Supernatant, Plasma, Serum
Produktnummer ABIN625166
  • Target Alle CCL19 ELISA Kits anzeigen
    CCL19 (Chemokine (C-C Motif) Ligand 19 (CCL19))
    Reaktivität
    • 8
    • 8
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    5-1000 pg/mL
    Untere Nachweisgrenze
    5 pg/mL
    Applikation
    ELISA
    Verwendungszweck
    Mouse MIP-3 beta (CCL19) ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Proben
    Plasma, Cell Culture Supernatant, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This ELISA kit shows no cross-reactivity with the following cytokines tested: Mouse CD30, L CD30, T CD40, CRG-2, CTACK, CXCL16, Eotaxin , Eotaxin-2, Fas Ligand, Fractalkine, GCSF, GM-CFS, IFN- gamma, IGFBP-3, IGFBP-5, IGFBP-6, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-3 Rb, IL-4, IL-5, IL-9, IL-10, IL-12 p40/p70, IL-12 p70, IL-13, IL-17, KC, Leptin R, LEPTIN(OB), LIX, L-Selectin, Lymphotactin, MCP-1, MCP- 5, M-CSF, MIG, MIP-1 alpha, MIP-1 gamma, MIP-2, MIP-3 beta, MIP-3 alpha, PF-4, PSelectin, RANTES, SCF, SDF-1 alpha, TARC, TCA-3, TECK, TIMP-1, TNF-alpha, TNF RI, TNF RII, TPO, VCAM-1, VEGF.
    Sensitivität
    5 pg/mL
    Produktmerkmale
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Bestandteile
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Benötigtes Material
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Zu unserem meistverkauften CCL19 ELISA Kit
    Top Product
    Discover our top product CCL19 ELISA Kit
  • Applikationshinweise
    Recommended Dilution for serum and plasma samples2 fold
    Probenmenge
    100 μL
    Plattentyp
    Pre-coated
    Protokoll
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Aufbereitung der Reagenzien
    1. Bring all reagents and samples to room temperature (18 - 25°C) before use. 2. Sample dilution: If your samples need to be diluted, Assay Diluent (Item E) is used for dilution of serum/plasma/culture supernatants. 3. Assay Diluent (Item E) should be diluted 5-fold with deionized or distilled water before use. 4. Preparation of standard: Briefly spin the vial of Item C. Add 400 µl 1x Assay Diluent (Item E) into Item C vial to prepare a 50 ng/ml standard solution. Dissolve the powder thoroughly by a gentle mix. Add 20 µl MIP-3-beta standard from the vial of tem C, into a tube with 980 µl 1x Assay Diluent to prepare a 1000 pg/ml standard solution. Pipette 300 µl 1x Assay Diluent into each tube. Use the 1000 pg/ml standard solution to produce a dilution series (shown below). Mix each tube thoroughly before the next transfer. Gently vortex to mix. 1x Assay Diluent serves as the zero standard (0 pg/ml). 5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer. 6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µl of 1x Assay Diluent into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4°C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent and used in step 4 of Part VI Assay Procedure. 7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 13,000-fold with 1x Assay Diluent. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 2 µl of HRP-Streptavidin concentrate into a tube with 198.0 µl 1x Assay Diluent to prepare a 100-fold diluted HRP-Streptavidin solution (do not store the diluted solution for next day use). Mix through and then pipette 70 µl of prepared 100-fold diluted solution into a tube with 9.1 ml 1x Assay Diluent to prepare a final 13,000 fold diluted HRP-Streptavidin solution.
    Testdurchführung
    1. Bring all reagents and samples to room temperature (18 - 25°C) before use. It is recommended that all standards and samples be run at least in duplicate. 2. Add 100 µl of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4°C with gentle shaking. 3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 µl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels. 4. Add 100 µl of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking. 5. Discard the solution. Repeat the wash as in step 3. 6. Add 100 µl of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking. 7. Discard the solution. Repeat the wash as in step 3. 8. Add 100 µl of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking. 9. Add 50 µl of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Ergebnisberechnung

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.

    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    -20 °C
    Informationen zur Lagerung
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Haltbarkeit
    6 months
  • Ibrahim, Barnes, Osorio, Anstead, Jimenez, Osterholzer, Travi, Ahuja, White, Melby: "Deficiency of lymph node-resident dendritic cells (DCs) and dysregulation of DC chemoattractants in a malnourished mouse model of Leishmania donovani infection." in: Infection and immunity, Vol. 82, Issue 8, pp. 3098-112, (2014) (PubMed).

  • Target Alle CCL19 ELISA Kits anzeigen
    CCL19 (Chemokine (C-C Motif) Ligand 19 (CCL19))
    Andere Bezeichnung
    MIP-3 Beta / CCL19 (CCL19 Produkte)
    Synonyme
    CKb11 ELISA Kit, ELC ELISA Kit, MIP-3b ELISA Kit, MIP3B ELISA Kit, SCYA19 ELISA Kit, CCL19 ELISA Kit, Scya19 ELISA Kit, exodus-3 ELISA Kit, C-C motif chemokine ligand 19 ELISA Kit, chemokine (C-C motif) ligand 19 ELISA Kit, CCL19 ELISA Kit, ccl19 ELISA Kit, Ccl19 ELISA Kit
    Hintergrund
    The Mouse MIP-3-beta (Macrophage Inflammatory Protein 3 beta) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of mouse MIP-3- beta in serum, plasma and cell culture supernatants. This assay employs an antibody specific for mouse MIP-3-beta coated on a 96-well plate. Standards and samples are pipetted into the wells and MIP-3-beta present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-mouse MIP-3-beta antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of MIP-3-beta bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. Reproducibility: Intra-Assay: CV<10% Inter-Assay: CV<12%.
    Gen-ID
    100039053, 24047
    UniProt
    O70460
    Pathways
    Positive Regulation of Immune Effector Process