COLEC12 IQ-ELISA Kit
-
- Target Alle COLEC12 IQ-ELISA Kits anzeigen
- COLEC12 (Collectin Sub-Family Member 12 (COLEC12))
-
Reaktivität
- Human
- Nachweismethode
- qPCR
- Methodentyp
- Sandwich ELISA
- Applikation
- ELISA
- Verwendungszweck
- Human Immunoquantitative (PCR-Based) Collectin-12 (CL-P1 ELISA Kit for cell culture supernatants, plasma, and serum samples.
- Proben
- Cell Culture Supernatant, Plasma, Serum
- Analytische Methode
- Semi-Quantitative
- Sensitivität
- 0.022 ng/mL
- Produktmerkmale
- IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
- Bestandteile
-
- Collectin-12 (CL-P1 Microplate (Item A): 96 well PCR plate coated with anti-Human Collectin-12 (CL-P1
- Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
- Standards (Item C): 2 vials of recombinant Human Collectin-12 (CL-P1
- Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
- Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
- Detection Affinity Reagent for Collectin-12 (CL-P1 (Item F): 2 vials of a 4x concentrated solution of anti-Human Collectin-12 (CL-P1 affinity reagent
- IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
- Primer Solution (Item I): 1.7 ml vial
- PCR Master Mix (Item J): 1.2 ml vial
- PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
- Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
- Benötigtes Material
-
- Real-time PCR instrument, Bio-Rad recommended
- Precision pipettes to deliver 2 μL to 1 mL volumes
- Adjustable 1-25 mL pipettes for reagent preparation
- 100 mL and 1 liter graduated cylinders
- Absorbent paper
- Distilled or deionized water
- Log-log graph paper or computer and software for data analysis
- Tubes to prepare standard or sample dilutions
- Heating block or water bath capable of 80°C
- Featured
- Zu unserem meistverkauften COLEC12 ELISA Kit
- Top Product
- Discover our top product COLEC12 ELISA Kit
-
-
- Applikationshinweise
- The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
- Kommentare
-
The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.
- Probenmenge
- 25 µL
- Plattentyp
- Pre-coated
- Protokoll
-
- Prepare all reagents, samples and standards as instructed
- Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
- Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
- Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
- Add 15μL Primer solution 10μL of PCR master mix to each well
- Run real-time PCR
- Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Lagerung
- 4 °C,-20 °C,-80 °C
- Informationen zur Lagerung
- May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
- Haltbarkeit
- 6 months
-
- Target Alle COLEC12 IQ-ELISA Kits anzeigen
- COLEC12 (Collectin Sub-Family Member 12 (COLEC12))
- Andere Bezeichnung
- Collectin-12 (CL-P1) (COLEC12 Produkte)
- Synonyme
- COLEC12 IQ-ELISA Kit, CLP1 IQ-ELISA Kit, NSR2 IQ-ELISA Kit, SCARA4 IQ-ELISA Kit, SRCL IQ-ELISA Kit, CL-P1 IQ-ELISA Kit, Scara4 IQ-ELISA Kit, hm:zeh0853 IQ-ELISA Kit, id:ibd2826 IQ-ELISA Kit, sb:cb377 IQ-ELISA Kit, si:ch211-212m21.5 IQ-ELISA Kit, collectin subfamily member 12 IQ-ELISA Kit, collectin sub-family member 12 IQ-ELISA Kit, COLEC12 IQ-ELISA Kit, colec12 IQ-ELISA Kit, Colec12 IQ-ELISA Kit
- Gen-ID
- 81035
- UniProt
- Q5KU26
- Pathways
- Activation of Innate immune Response
-