Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

L1CAM IQ-ELISA Kit

L1CAM Reaktivität: Human qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
Produktnummer ABIN6385894
  • Target Alle L1CAM IQ-ELISA Kits anzeigen
    L1CAM (L1 Cell Adhesion Molecule (L1CAM))
    Reaktivität
    • 4
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    qPCR
    Methodentyp
    Sandwich ELISA
    Applikation
    ELISA
    Verwendungszweck
    Human Immunoquantitative (PCR-Based) L1CAM ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Proben
    Cell Culture Supernatant, Plasma, Serum
    Analytische Methode
    Semi-Quantitative
    Sensitivität
    0.08 pg/mL
    Produktmerkmale
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Bestandteile
    • L1CAM Microplate (Item A): 96 well PCR plate coated with anti-Human L1CAM
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human L1CAM
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for L1CAM (Item F): 2 vials of a 4x concentrated solution of anti-Human L1CAM affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Benötigtes Material
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Zu unserem meistverkauften L1CAM ELISA Kit
    Top Product
    Discover our top product L1CAM ELISA Kit
  • Applikationshinweise
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Kommentare

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Probenmenge
    25 µL
    Plattentyp
    Pre-coated
    Protokoll
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    4 °C,-20 °C,-80 °C
    Informationen zur Lagerung
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Haltbarkeit
    6 months
  • Target Alle L1CAM IQ-ELISA Kits anzeigen
    L1CAM (L1 Cell Adhesion Molecule (L1CAM))
    Andere Bezeichnung
    L1CAM (L1CAM Produkte)
    Synonyme
    l1cam-a IQ-ELISA Kit, CAML1 IQ-ELISA Kit, CD171 IQ-ELISA Kit, HSAS IQ-ELISA Kit, HSAS1 IQ-ELISA Kit, MASA IQ-ELISA Kit, MIC5 IQ-ELISA Kit, N-CAM-L1 IQ-ELISA Kit, N-CAML1 IQ-ELISA Kit, NCAM-L1 IQ-ELISA Kit, S10 IQ-ELISA Kit, SPG1 IQ-ELISA Kit, L1 IQ-ELISA Kit, Hsas IQ-ELISA Kit, Hyd IQ-ELISA Kit, NCAML1 IQ-ELISA Kit, L1 cell adhesion molecule S homeolog IQ-ELISA Kit, L1 cell adhesion molecule IQ-ELISA Kit, l1cam.S IQ-ELISA Kit, L1CAM IQ-ELISA Kit, L1cam IQ-ELISA Kit
    Gen-ID
    3897
    UniProt
    P32004
    Pathways
    Synaptic Membrane
Sie sind hier:
Kundenservice