CD44 ELISA Kit
-
- Target Alle CD44 ELISA Kits anzeigen
- CD44
-
Reaktivität
- Human
- Nachweismethode
- Colorimetric
- Methodentyp
- Sandwich ELISA
- Detektionsbereich
- 78 pg/mL - 5000 pg/mL
- Untere Nachweisgrenze
- 78 pg/mL
- Applikation
- ELISA
- Verwendungszweck
- For the quantitative determination of human cluster of differentiation (CD44) concentrations in serum, plasma, cell culture supernates, tissue homogenates.
- Proben
- Cell Culture Supernatant, Plasma, Serum, Tissue Homogenate
- Analytische Methode
- Quantitative
- Spezifität
- This assay has high sensitivity and excellent specificity for detection of human CD44. No significant cross-reactivity or interference between human CD44 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human CD44 and all the analogues, therefore, cross reaction may still exist.
- Sensitivität
- 19.5 pg/mL
- Bestandteile
-
- Assay plate
- Standard
- HRP-avidin (100 x concentrate)
- Biotin-antibody (100 x concentrate)
- Sample Diluent
- HRP-avidin Diluent
- Biotin-antibody Diluent
- Wash Buffer (25 x concentrate)
- TMB Substrate
- Stop Solution
- Adhesive Strip
- Top Product
- Discover our top product CD44 ELISA Kit
-
-
- Applikationshinweise
- Optimal working dilution should be determined by the investigator.
- Probenmenge
- 100 μL
- Testdauer
- 1 - 4.5 h
- Plattentyp
- Pre-coated
- Protokoll
-
- Prepare reagents, samples and standards as instructed.
- Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
- Remove the liquid of each well, don't wash.
- Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
- Aspirate and wash 3 times.
- Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
- Aspirate and wash 5 times.
- Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
- Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
- Aufbereitung der Reagenzien
-
- Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
- HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
- Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
- Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 5000 pg/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (5000 pg/mL). Sample Diluent serves as the zero standard (0 pg/mL).
- Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
- Bring all reagents to room temperature (18-25 °C) before use for 30 min.
- Prepare fresh standard for each assay. Use within 4 hours and discard after use.
- Making serial dilution in the wells directly is not permitted.
- Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
- Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
- Aufbereitung der Proben
-
- It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
- If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
- If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
- Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
Note:Recommend to dilute the serum or plasma samples with Sample Diluent (1:400) before test. The suggested 400-fold dilution can be achieved by adding 5 μL sample to 95 μL of Sample Diluent. Complete the 400-fold dilution by adding 15 μL of this solution to 285 μL of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments. - Testpräzision
-
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. - Beschränkungen
- Nur für Forschungszwecke einsetzbar
-
- Lagerung
- 4 °C,-20 °C
- Informationen zur Lagerung
- Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
- Haltbarkeit
- 6 months
-
-
miR146a up-regulation is involved in small HA oligosaccharides-induced pro-inflammatory response in human chondrocytes." in: Biochimica et biophysica acta. General subjects, pp. 129731, (2020) (PubMed).
: "
-
miR146a up-regulation is involved in small HA oligosaccharides-induced pro-inflammatory response in human chondrocytes." in: Biochimica et biophysica acta. General subjects, pp. 129731, (2020) (PubMed).
-
- Target Alle CD44 ELISA Kits anzeigen
- CD44
- Andere Bezeichnung
- CD44 molecule (Indian blood group) (CD44 Produkte)
- Synonyme
- CDW44 ELISA Kit, CSPG8 ELISA Kit, ECMR-III ELISA Kit, HCELL ELISA Kit, HUTCH-I ELISA Kit, IN ELISA Kit, LHR ELISA Kit, MC56 ELISA Kit, MDU2 ELISA Kit, MDU3 ELISA Kit, MIC4 ELISA Kit, Pgp1 ELISA Kit, AU023126 ELISA Kit, AW121933 ELISA Kit, AW146109 ELISA Kit, HERMES ELISA Kit, Ly-24 ELISA Kit, Pgp-1 ELISA Kit, CD44A ELISA Kit, METAA ELISA Kit, RHAMM ELISA Kit, XCD44 ELISA Kit, cd44 ELISA Kit, cdw44 ELISA Kit, cspg8 ELISA Kit, ecmr-iii ELISA Kit, hcell ELISA Kit, lhr ELISA Kit, mc56 ELISA Kit, mdu2 ELISA Kit, mdu3 ELISA Kit, mic4 ELISA Kit, mutch-i ELISA Kit, pgp1 ELISA Kit, CD44 molecule (Indian blood group) ELISA Kit, syndecan 4 ELISA Kit, CD44 antigen ELISA Kit, CD44 molecule (Indian blood group) S homeolog ELISA Kit, CD44 ELISA Kit, SDC4 ELISA Kit, Cd44 ELISA Kit, cd44.S ELISA Kit
- Hintergrund
-
Abbreviation: CD44
Alias: CDW44, CSPG8, ECMR-III, HCELL, IN, LHR, MC56, MDU2, MDU3, MGC10468, MIC4, MUTCH-I, Pgp1, CD44 antigen|CD44 antigen (homing function and Indian blood group system)|CDW44 antigen|GP90 lymphocyte homin
- UniProt
- P16070
- Pathways
- Glycosaminoglycan Metabolic Process, Autophagie, Negative Regulation of intrinsic apoptotic Signaling
-