HMGB1 ELISA Kit

Instant HMGB1 Reaktivität: Human Colorimetric Sandwich ELISA 62.5 pg/mL - 4000 pg/mL Plasma, Serum
Produktnummer ABIN7035631
  • Target Alle HMGB1 ELISA Kits anzeigen
    HMGB1 (High Mobility Group Box 1 (HMGB1))
    Reaktivität
    • 7
    • 4
    • 4
    • 4
    • 4
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    62.5 pg/mL - 4000 pg/mL
    Untere Nachweisgrenze
    62.5 pg/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is an instand sandwich enzyme immunoassay for in vitro quantitative measurement in various sample types.
    Proben
    Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of High Mobility Group Protein 1.
    Sensitivität
    22.5 pg/mL
    Güteklasse
    Instant
    Bestandteile
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Top Product
    Discover our top product HMGB1 ELISA Kit
  • Probenmenge
    100 µL
    Testdauer
    1.5 h
    Plattentyp
    Pre-coated
    Protokoll
    1. Prepare all reagents, samples and standards,
    2. Add 100μL standard or sample to each well. Incubate 30 minutes at 37 °C,
    3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 30 minutes at 37 °C,
    4. Aspirate and wash 5 times,
    5. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C,
    6. Aspirate and wash 5 times,
    7. Add 90μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
    8. Add 50μL Stop Solution. Read at 450nm immediately.
    Aufbereitung der Reagenzien
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 1.0 mL of Standard Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 2,000pg/mL. Firstly dilute the stock solution to 1,000 pg/mL and the diluted standard serves as the highest standard (1,000 pg/mL). Then prepare 7 tubes containing 0.5 mL Standard Diluent and produce a double dilution series by transferring 500 µL each. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 1,000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.2pg/mL, 15.6pg/mL, and the last microcentrifuge tube with Standard Diluent is the blank as 0pg/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stockDetection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 20 mL of Wash Solution concentrate (30x) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standard within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for once pipetting.
    4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    5. Prepare Substrate working Solution within 15 minutes before assay.
    6. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    7. Contaminated water or container for reagent preparation will influence the detection result.
    Aufbereitung der Proben
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Testpräzision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level of target were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level of target were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV < 10%
    Inter-Assay: CV < 12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Lagerung
    4 °C/-20 ° C
    Informationen zur Lagerung
    1. For unopened kit: All reagents should be stored according to the labels on the vials. The Standard, Detection Reagent A, Detection Reagent B, and 96-well Strip Plate should be stored at -20 °C upon receipt, while the other reagents should be stored at 4 °C.
    2. For opened kits: the remaining reagents must be stored according to the above storage conditions. In addition, please return the unused wells to the foil pouch containing the desiccant and seal the foil pouch with the zipper.
    Haltbarkeit
    6 months
  • Target Alle HMGB1 ELISA Kits anzeigen
    HMGB1 (High Mobility Group Box 1 (HMGB1))
    Andere Bezeichnung
    High Mobility Group Protein 1 (HMGB1 Produkte)
    Synonyme
    HMG1 ELISA Kit, HMG3 ELISA Kit, SBP-1 ELISA Kit, DEF ELISA Kit, HMG-1 ELISA Kit, Hmg1 ELISA Kit, amphoterin ELISA Kit, p30 ELISA Kit, hmgb1 ELISA Kit, ik:tdsubc_1a5 ELISA Kit, wu:fb23c02 ELISA Kit, xx:tdsubc_1a5 ELISA Kit, zgc:56110 ELISA Kit, zgc:77104 ELISA Kit, hmg-1 ELISA Kit, hmg3 ELISA Kit, sbp-1 ELISA Kit, hmg1 ELISA Kit, HMGB1 ELISA Kit, Ac2-008 ELISA Kit, high mobility group box 1 ELISA Kit, high-mobility group box 1 ELISA Kit, high mobility group box 1a ELISA Kit, high mobility group box 1 L homeolog ELISA Kit, high mobility group protein B1 ELISA Kit, HMGB1 ELISA Kit, Hmgb1 ELISA Kit, hmgb1 ELISA Kit, hmgb1a ELISA Kit, hmgb1.L ELISA Kit, LOC100359149 ELISA Kit
    Hintergrund
    HMG1, HMG3, SBP1, Sulfoglucuronyl Carbohydrate Binding Protein, Amphoterin, High Mobility Group Box 1 Protein
    Pathways
    p53 Signalweg, Regulation of Muscle Cell Differentiation, Skeletal Muscle Fiber Development, Positive Regulation of Endopeptidase Activity, Regulation of Carbohydrate Metabolic Process, Toll-Like Receptors Cascades, Smooth Muscle Cell Migration, Inflammasome
Sie sind hier: